ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Automatic quantification of left ventricular function by medical students using ultrasound

Jahn Frederik, Grue; Sigurd, Storve; Håvard, Dalen; Ole Christian, Mjølstad; Stein O., Samstad; Torfinn, Eriksen-Volnes; Hans, Torp; Bjørn Olav, Haugen
BMC MEDICAL IMAGING2020-12DOI: 10.1186/s12880-020-00430-1
6阅读
引用收藏
分享

摘要

<jats:title>Abstract</jats:title><jats:sec> <jats:title>Background</jats:title> <jats:p>Automatic analyses of echocardiograms may support inexperienced users in quantifying left ventricular (LV) function. We have developed an algorithm for fully automatic measurements of mitral annular plane systolic excursion (MAPSE) and mitral annular systolic (S′) and early diastolic (e′) peak velocities. We aimed to study the influence of user experience of automatic measurements of these indices in echocardiographic recordings acquired by medical students and clinicians.</jats:p> </jats:sec><jats:sec> <jats:title>Methods</jats:title> <jats:p>We included 75 consecutive patients referred for echocardiography at a university hospital. The patients underwent echocardiography by clinicians (cardiologists, cardiology residents and sonographers), who obtained manual reference measurements of MAPSE by M-mode and of S′ and e′ by colour tissue Doppler imaging (cTDI). Immediately after, each patient was examined by 1 of 39 medical students who were instructed in image acquisition on the day of participation. Each student acquired cTDI recordings from 1 to 4 patients. All cTDI recordings by students and clinicians were analysed for MAPSE, S′ and e′ using a fully automatic algorithm. The automatic measurements were compared to the manual reference measurements.</jats:p> </jats:sec><jats:sec> <jats:title>Results</jats:title> <jats:p>Correct tracking of the mitral annulus was feasible in 50 (67%) and 63 (84%) of the students’ and clinicians’ recordings, respectively (<jats:italic>p</jats:italic> = 0.007). Image quality was highest in the clinicians’ recordings. Mean difference ± standard deviation of the automatic measurements of the students’ recordings compared to the manual reference was − 0.0 ± 2.0 mm for MAPSE, 0.3 ± 1.1 cm/s for S′ and 0.6 ± 1.4 cm/s for e′. The corresponding intraclass correlation coefficients for MAPSE, S′ and e′ were 0.85 (good), 0.89 (good) and 0.92 (excellent), respectively. Automatic measurements from the students’ and clinicians’ recordings were in similar agreement with the reference when mitral annular tracking was correct.</jats:p> </jats:sec><jats:sec> <jats:title>Conclusions</jats:title> <jats:p>In case of correct tracking of the mitral annulus, the agreement with reference for the automatic measurements was overall good. Low image quality reduced feasibility. Adequate image acquisition is essential for automatic analyses of LV function indices, and thus, appropriate education of the operators is mandatory. Automatic measurements may help inexperienced users of ultrasound, but do not remove the need for dedicated education and training.</jats:p> </jats:sec>

引用文献 (1)相关
加载中…
  • Heart
    Julia, Nesteruk; Hendrikus J , Duckers; Bodo E , Strauer; Gustav, SteinhoffRegenerative Medicine - from Protocol to Patient, Springer International Publishing, 59-109, 2016.

发表信息

论文状态
公开发表
期刊
BMC MEDICAL IMAGING
发表日期
2020-12
卷期
第 20 卷, 第 1 期
页码
29
DOI
10.1186/s12880-020-00430-1
语言
ENGLISH
期刊收录
NSL.SCIE
期刊等级
4区
资助标注
Norges Forskningsr&aring;d[237887]

作者

  • J

    Jahn Frederik, Grue (第一作者)

  • S

    Sigurd, Storve

查看全部 8 位作者收起作者
  • H

    Håvard, Dalen

  • O

    Ole Christian, Mjølstad

  • S

    Stein O., Samstad

  • T

    Torfinn, Eriksen-Volnes

  • H

    Hans, Torp

  • B

    Bjørn Olav, Haugen

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417