The "Half-Perc" technique using a simple modified metal trocar for peritoneal dialysis catheter placement: results of a 3-year follow-up of 280 patients and a literature review

Zhang, Difei; Li, Rongrong; He, Jingwen; Peng, Yu*; Liu, Hui; Liu, Xusheng; Lu, Fuhua*
Science Citation Index Expanded
广东省人民医院; 广州中医药大学; y

摘要

Purpose There is an ongoing debate about the ideal technique for peritoneal dialysis (PD) catheter insertion in patients with end-stage renal disease (ESRD). A half-percutaneous ("Half-Perc") technique shares some of the advantages of both percutaneous technique and traditional open surgery. This retrospective study aimed to evaluate the clinical feasibility, safety, and effects of the "Half-Perc" technique for PD catheter placement, and to compare the clinical outcomes of the "Half-Perc" technique with various imaging-assisted percutaneous techniques from the current literature. Methods We included 280 consecutive patients with ESRD who underwent the "Half-Perc" insertion of the first PD catheter between September 2016 and September 2019. We recorded baseline characteristics, operative parameters, catheter-related complications, catheter survival, and the reason behind PD cessation. Results We included 174 men and 106 women, with a mean age of 50.4 years (range, 11-85 years). The mean operative time was 28.8 min (range, 15-38 min) and technical success rate was observed in 278 patients (99.3%). There were 28 episodes (10%) of mechanical complications with initial catheters occurring during the follow-up. Catheter malfunctions were the most common mechanical complication and were observed in 15 patients. Peritonitis was the most frequent catheter-related complication, with 32 episodes of peritonitis observed in 29 (10.4%) patients. After a mean follow-up period of 15.4 months (range, 2-36 months), 235 patients (83.9%) survived with their initial PD catheter by the end of the study. Of the 280 patients analyzed, 35 patients (12.5%) ceased PD at some stage during follow-up. The most common reason for PD cessation was kidney transplantation (18 patients (6.4%)), followed by death (9 patients (3.2%)) and switch to hemodialysis (HD) (7 patients (2.5%)), and recovery of renal failure (1 patient (0.4%)). Conclusion The "Half-Perc" technique, including a modified metal trocar, is a simple, safe, and effective method for PD catheter placement that can be used for patients with ESRD.

关键词

Peritoneal dialysis "Half-Perc" catheter placement Catheter-related complications Catheter survival End-stage renal disease