摘要
Purpose: To test the direct influence of the reference respiratory position on image quality for self-navigated whole-heart coronary MRI. Methods: Self-navigated whole-heart coronary MRI was performed in 11 healthy adult subjects. Respiratory motion was compensated for by using three different respiratory reference positions of the heart: end-inspiratory, end-expiratory, and the mean of the entire respiratory excursion. All datasets were reconstructed without motion compensation for comparison. Image quality was assessed in all reconstructions using signal-to-noise ratio (SNR) and contrst-to-noise ratio (CNR) measurements, as well as percentage vessel sharpness and visible length of the coronary arteries. Results: While SNR and CNR remained close to constant in all reconstructions, a clear and significant improvement in vessel sharpness was identified in all motion corrected datasets with respect to their uncorrected counterpart (e.g., percentage sharpness of the proximal right coronary artery (RCA): 61.6+/-8.2% for end-inspiration, 64.1+/-10.7% for end-expiration, and 63.3+/-7.0% for the mean respiratory position versus 55.0+/-10.4 for the uncorrected datasets; P<0.05). Among all motion corrected reconstructions, the use of an end-expiratory reference position most consistently provided the highest image quality. In particular, some of the improvements in vessel sharpness and length measured for end-expiration were statistically significant with respect to the reconstructions performed at end-inspiration (e.g., percentage sharpness of the proximal left anterior descending coronary: 58.2+/-7.4% versus 55.8+/-8.4%; P<0.05; and visible length of the RCA: 125.7+/-25.9 mm versus 114.4+/-27.4 mm; P<0.05). Conclusion: The use of end-expiration as a reference position for respiratory motion correction in free-breathing self-navigated whole heart coronary MRA significantly improves image quality.
学科与关键词
- Postcontrast Whole- Heart Coronary MR Angiography: Initial Experience in PatientsPiccini, Davide; Monney, Pierre; Sierro, Christophe; Coppo, Simone; Bonanno, Gabriele; van Heeswijk, Ruud B.; Chaptinel, Jerome; Vincenti, Gabriella; de Blois, Jonathan; Koestner, Simon C.; Rutz, Tobias; Littmann, Arne; Zenge, Michael O.; Schwitter, Juerg; Stuber, Matthias*RADIOLOGY, 2014, 270(2): 378-386.被引 89
- Four-Dimensional Respiratory Motion-Resolved Whole Heart Coronary MR AngiographyPiccini, Davide*; Feng, Li; Bonanno, Gabriele; Coppo, Simone; Yerly, Jerome; Lim, Ruth P.; Schwitter, Juerg; Sodickson, Daniel K.; Otazo, Ricardo; Stuber, MatthiasMagnetic Resonance in Medicine, 2017, 77(4): 1473-1484.被引 73
- High Efficiency Coronary MR Angiography with Nonrigid Cardiac Motion CorrectionPang, Jianing; Chen, Yuhua; Fan, Zhaoyang; Nguyen, Christopher; Yang, Qi; Xie, Yibin; Li, Debiao*Magnetic Resonance in Medicine, 2016, 76(5): 1345-1353.被引 19