Attenuation-based Automatic Tube Voltage Selection and Tube Current Modulation for Dose Reduction at Contrast-enhanced Liver CT

Lee, Kyung Hee; Lee, Jeong Min*; Moon, Sung Kyoung; Baek, Jee Hyun; Park, Ji Hoon; Flohr, Thomas G.; Kim, Kyung Won; Kim, Soo Jin; Han, Joon Koo; Choi, Byung Ihn
RADIOLOGY2012-11DOI: 10.1148/radiol.12112434
80被引1阅读
引用收藏
分享

摘要

Purpose: To retrospectively determine whether the combined use of automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) can effectively reduce radiation dose at contrast material-enhanced liver computed tomography (CT) while maintaining acceptable image quality compared with the use of ATCM alone. Materials and Methods: This study was approved by an institutional review board, and informed consent was waived. Three hundred fourteen consecutive patients suspected of having liver disease were divided into three groups. In two groups, both ATVS and ATCM were used (group A1, n = 97; group A2, n = 101) but with different contrast gain settings; in one group, only ATCM with a fixed tube potential of 120 kV (group B, n = 116) was used. Weighted volume CT dose index and dose-length product, contrast-to-noise ratios (CNRs), and mean image noise were assessed. Qualitative analysis was performed by two board-certified radiologists and one radiology resident. Statistical analysis was performed by using the one-way analysis of variance test, two-tailed paired t test, Kruskal-Wallis test, and noninferiority test. Results: In groups A1 and A2, a significant dose reduction was obtained compared with that in group B (P < .0001). The mean dose reduction was 20% in group A1 and 31% in group A2. Furthermore, CNRs were significantly higher in groups A1 and A2 than in group B (P < .0001). Despite the higher image noise in groups A1 and A2, the overall image quality was acceptable. Conclusion: Compared with the use of ATCM alone, the combined use of ATVS and ATCM allowed reduction of radiation exposure while maintaining good image quality at contrast-enhanced liver CT.

学科与关键词

关键词
STATISTICAL ITERATIVE RECONSTRUCTIONINITIAL CLINICAL-EXPERIENCEIMPROVED IMAGE QUALITYMULTIDETECTOR ROW CTABDOMINAL CTCOMPUTED-TOMOGRAPHYRADIATION-EXPOSUREPATIENT SIZEOPTIMIZATIONFEASIBILITY
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
RADIOLOGY
发表日期
2012-11
卷期
第 265 卷, 第 2 期
页码
437-447
DOI
10.1148/radiol.12112434
语言
ENGLISH
成果收录
SCIE
资助标注
Bayer Healthcare; GE Healthcare

作者

  • L

    Lee, Kyung Hee (第一作者)

  • L

    Lee, Jeong Min (通讯)

查看全部 10 位作者收起作者
  • M

    Moon, Sung Kyoung

  • B

    Baek, Jee Hyun

  • P

    Park, Ji Hoon

  • F

    Flohr, Thomas G.

  • K

    Kim, Kyung Won

  • K

    Kim, Soo Jin

  • H

    Han, Joon Koo

  • C

    Choi, Byung Ihn

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417