High-Pitch Electrocardiogram-Triggered Computed Tomography of the Chest Initial Results

Lell, Michael*; Hinkmann, Fabian; Anders, Katharina; Deak, Paul; Kalender, Willi A.; Uder, Michael; Achenbach, Stephan河北医科大学
Investigative Radiology2009-11DOI: 10.1097/RLI.0b013e3181b9df7e
70被引1阅读
引用收藏
分享

摘要

Objectives: Chest pain is one of the most frequent symptoms in the emergency department. A variety of different diseases, some of them acutely life threatening, can be the underlying cause. Electrocardiogram (ECG)gated computed tomography angiography of the thorax has been proposed as a cost and time effective imaging technique for these patients. We describe a new high-pitch scan mode, which has been developed specifically for low-dose ECG-triggered computed tomography angiography using dual source computed tomography (CT). Material and Methods: Twenty-four patients were examined with this technique on a second generation dual source CT system. The scan mode uses a pitch of 3.2 to acquire a spiral CT data set of the complete thorax in less than I second with a temporal resolution of 75 ms (scan parameters: 128 X 0.6 mm collimation, 0.28 seconds gantry rotation time, 370 mAs at 100 kV [15 patients] and 320 mAs at 120 kV [9 patients], reconstructed slice thickness 0.6 mm, increment 0.4 mm). Data acquisition was prospectively triggered at 50% to 60% of the RR interval to cover the range over the heart in diastole. A triple phase contrast injection protocol (total volume: 80 mL) was used to optimize enhancement of the pulmonary and systemic arterial vessels. Image quality was evaluated using a 4-point scale (1 = absence of motion artifacts; 2 = slight motion artifacts, fully evaluable; 3 = motion artifacts, but evaluable; 4 = unevaluable) on a per-segment basis. Results: The patients had an average heart rate of 68 +/- 15 bpm (range: 43-111 bpm) during data acquisition. Motion artifact free visualization of the aorta and pulmonary vessels was possible in each case, of 344 coronary artery segments, 242 (70%) had an image quality score of 1, 60 segments (17%) a score of 2, 28 segments (8%) a score of 3, and 14 segments (4%) were rated as "unevaluable." In 17 patients (10 patients with a heart rate <= 60 bpm) all segments were evaluable. The average dose length product was 113 +/- 11 mGy x cm per scan (mean effective dose 1.6 +/- 0.2 mSv) at 100 kV and 229 +/- 31 mGy x cm per scan (mean effective dose 3.2 +/- 0.4 mSv) at 120 kV. Conclusion: Our initial results indicate that this high-pitch scan mode allows motion artifact free and accurate visualization of the thoracic vessels, and diagnostic image quality of the coronary arteries in patients with low and stable heart rates at a very low radiation exposure.

学科与关键词

关键词
computed tomographypulmonary embolismaortic dissectioncoronary CT angiographydual source CTradiation exposure
相关
加载中…
  • Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience
    Wang, Q.; Qin, J.; He, B.; Zhou, Y.; Yang, J-J; Hou, X. -L.; Yang, X. -B.; Chen, J. -H.; Chen, Y. -D.*Clinical Radiology, 2013, 68(8): 792-798.被引 4
  • ECG-triggered high-pitch CT for simultaneous assessment of the aorta and coronary arteries
    Hachulla, Anne-Lise*; Ronot, Maxime; Noble, Stephane; Becker, Christoph D.; Montet, Xavier; Vallee, Jean-PaulJournal of Cardiovascular Computed Tomography, 2016, 10(5): 407-413.被引 8
  • Reduction of Thoracic Aorta Motion Artifact With High-Pitch 128-Slice Dual-Source Computed Tomographic Angiography: A Historical Control Study
    Nakagawa, Junichiro; Tasaki, Osamu*; Watanabe, Yoshiyuki; Azuma, Takeo; Ohnishi, Mitsuo; Ukai, Isao; Tahara, Kenichi; Ogura, Hiroshi; Kuwagata, Yasuyuki; Hamasaki, Toshimitsu; Shimazu, TakeshiJournal of Computer Assisted Tomography, 2013, 37(5): 755-759.被引 9
查看全部 →

发表信息

论文状态
公开发表
期刊
Investigative Radiology
发表日期
2009-11
卷期
第 44 卷, 第 11 期
页码
728-733
DOI
10.1097/RLI.0b013e3181b9df7e
语言
ENGLISH
成果收录
SCIE
资助标注
Bundesministerium fur Bildung und Forschung (BMBF), Bonn, Germany [01 EV 0708]

作者

  • L

    Lell, Michael (通讯) (第一作者)

  • H

    Hinkmann, Fabian

查看全部 7 位作者收起作者
  • A

    Anders, Katharina

  • D

    Deak, Paul

    inst med

  • K

    Kalender, Willi A.

    inst med

  • U

    Uder, Michael

  • A

    Achenbach, Stephan

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417