ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Using the sEMG signal representativity improvement towards upper-limb movement classification reliability

Cene, Vinicius Horn*; Balbinot, Alexandre
Biomedical Signal Processing and Control2018-9DOI: 10.1016/j.bspc.2018.07.014
10被引2阅读
引用收藏
分享

摘要

Several Machine Learning techniques have been employed to process sEMG signals in order to provide a reliable control biosignal. Although some papers report accuracy rates superior to 90%, there is a lack of more detailed reasoning for reliable systems capable of providing control signals to users that may, for instance, control a prosthetic device. In this paper, we combined two strategies in order to increase the representativity of the sEMG signals: (a) the use of a stochastic filter based on Antonyan Vardan Transform (AVT) prior the extraction of the signal features that reduces the stochastic behavior of the sEMG signal; and (b) a novel sEMG feature called Differential Enhanced Signal (DES), designed to increase the signal representativity in the sEMG transition sections where features based on time-domain are usually inefficient. Thus, using only RMS and DES features, we were able to mitigate the class overlap in the transition sections and consequentially increase the overall classification accuracy for training and testing of the system. Since a reliable output signal is desired to perform ultimate prosthetic control, a reliability metric was defined and evaluated, and once a non-reliable classification is detected, the system autonomously activates auxiliary methods based on post-processing and data discard to maintain the classification consistency. Three preliminary scenarios involving the AVT filter, a Wavelet filter and the unfiltered signal were compared in terms of accuracy rate to define the most efficient filtering technique. The signal representation using the combination of RMS and DES features was also compared to a set of Time Domain (TD) features to test its enhancement capabilities. The AVT-based filter and the DES feature were able to present higher accuracy rates in both accuracy scenarios tested. Three different databases including 60 subjects among amputees and non-amputees were used to appraise the system, which was able to reach a mean accuracy rate of 99.1% in the best-case scenario.

学科与关键词

关键词
Upper-limbExtreme learning machinesEMGReliabilityIEEDifferential Enhanced Signal
相关
加载中…
  • Resilient EMG Classification to Enable Reliable Upper-Limb Movement Intent Detection
    Cene, Vinicius Horn*; Balbinot, AlexandreIEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28(11): 2507-2514.被引 11
  • EMG Based Control of Transhumeral Prosthesis Using Machine Learning Algorithms
    Sattar, Neelum Yousaf*; Kausar, Zareena; Usama, Syed Ali; Farooq, Umer; Khan, Umar ShahbazINTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2021, 19(10): 3522-3532.被引 15
  • Recent trends and challenges of surface electromyography in prosthetic applications
    Yadav, Drishti; Veer, Karan*Biomedical Engineering Letters, 2023, 13(3): 353-373.被引 9
查看全部 →

发表信息

论文状态
公开发表
期刊
Biomedical Signal Processing and Control
发表日期
2018-09
卷期
第 46 卷
页码
182-191
DOI
10.1016/j.bspc.2018.07.014
语言
ENGLISH
期刊等级
Q2
成果收录
SCIE
资助标注
Brazilian Coordination for Improvement of Higher Level Personnel (CAPES)

作者

  • C

    Cene, Vinicius Horn (通讯) (第一作者)

  • B

    Balbinot, Alexandre

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417