ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Improved Opacification of a Suboptimally Enhanced Pulmonary Artery in Chest CT: Experience Using a Dual-Layer Detector Spectral CT

Bae, Kyungsoo; Jeon, Kyung Nyeo*; Cho, Soo Buem; Park, Sung Eun; Moon, Jin Il; Baek, Hye Jin; Choi, Bo Hwa
American Journal of Roentgenology2018-4DOI: 10.2214/AJR.17.18537
33被引13阅读
引用收藏
分享

摘要

OBJECTIVE. The objective of our study was to evaluate the quality of virtual monoenergetic imaging (VMI) from dual-layer detector spectral CT and the effect of virtual monoenergetic images obtained at low energies on the detection of pulmonary embolism (PE) in patients with a suboptimally enhanced pulmonary artery on chest CT. MATERIALS AND METHODS. Of 1552 consecutive chest CT examinations performed with dual-layer detector spectral CT using a routine protocol with a tube voltage of 120 kVp, 79 examinations with suboptimal enhancement of the pulmonary artery (i.e., mean attenuation of pulmonary artery <= 180 HU) were included. The mean attenuation of the pulmonary artery, noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of virtual monoenergetic images obtained at 40-200 keV were compared with those of the conventional 120-kVp images. The virtual monoenergetic images with the best CNR were compared with the 120-kVp images with regard to subjective image quality and diagnostic accuracy for detecting PE. RESULTS. Sufficient attenuation of the pulmonary artery (> 180 HU) was obtained using VMI for 78 of the 79 examinations. The noise levels of the virtual monoenergetic images were gradually increased with decreasing energy level (i.e., kiloelectron volt setting). The CNR and SNR of virtual monoenergetic images at 40-65 keV were significantly higher (both, p < 0.001) than the CNR and SNR of the 120-kVp images. The CNR was the highest at 40 keV for all cases. Diagnostic accuracy for detecting PE was significantly higher for 40-keV images (reader 1: AUC = 0.992, p = 0.033; reader 2: AUC = 0.986, p = 0.043) than for 120-kVp images (reader 1, AUC = 0.911; reader 2, AUC = 0.933). The subjective quality was not different between these two images. CONCLUSION. In chest CT examinations in which the pulmonary artery is suboptimally enhanced, obtaining virtual monoenergetic images at a low energy setting using dual-layer detector spectral CT allows sufficient attenuation of the pulmonary artery to be achieved while preserving image quality and increasing diagnostic performance for detecting PE.

学科与关键词

关键词
chest CTpulmonary arteryspectral CTsuboptimal contrast enhancementvirtual monoenergetic imagevirtual monoenergetic imaging (VMI)
相关
加载中…
  • Incremental improvement of diagnostic performance of coronary CT angiography for the assessment of coronary stenosis in the presence of calcium using a dual-layer spectral detector CT: validation by invasive coronary angiography
    Xu, Cheng; Yi, Yan; Han, Yechen; Xie, Hongzhi; Lu, Xiaomei; Vembar, Mani; Leiner, Tim; Jin, Zhengyu; Wang, Yining*International Journal of Cardiovascular Imaging, 2021, 37(8): 2561-2572.被引 8
  • Impact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels
    Dillinger, Daniel*; Overhoff, Daniel; Booz, Christian; Kaatsch, Hanns L.; Piechotka, Joel; Hagen, Achim; Froelich, Matthias F.; Vogl, Thomas J.; Waldeck, StephanDiagnostics, 2023, 13(5): 938.被引 21
  • Spectral detector CT for cardiovascular applications
    Rajiah, Prabhakar*; Abbara, Suhny; Halliburton, Sandra SimonDiagnostic and Interventional Radiology, 2017, 23(3): 187-193.被引 44
查看全部 →

发表信息

论文状态
公开发表
期刊
American Journal of Roentgenology
发表日期
2018-04
卷期
第 210 卷, 第 4 期
页码
734-741
DOI
10.2214/AJR.17.18537
语言
ENGLISH
期刊等级
Q1
成果收录
SCIE

作者

  • B

    Bae, Kyungsoo (第一作者)

  • J

    Jeon, Kyung Nyeo (通讯)

查看全部 7 位作者收起作者
  • C

    Cho, Soo Buem

  • P

    Park, Sung Eun

  • M

    Moon, Jin Il

  • B

    Baek, Hye Jin

  • C

    Choi, Bo Hwa

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417