ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction

Isola, A. A.*; Metz, C. T.; Schaap, M.; Klein, S.; Grass, M.; Niessen, W. J.
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS2012-4DOI: 10.1016/j.compmedimag.2011.12.005
15被引4阅读
引用收藏
分享

摘要

In this paper a method which combines iterative computed tomography reconstruction and coronary centerline extraction technique to obtain motion artifact-free reconstructed images of the coronary arteries are proposed and evaluated. The method relies on motion-vector fields derived from a set of coronary centerlines extracted at multiple cardiac phases within the R-R interval. Hereto, start and end points are provided by the user in one time-frame only. Using an elastic image registration, these points are propagated to all the remaining cardiac phases. Consequently, a multi-phase three-dimensional coronary centerline is determined by applying a semi-automatic minimum cost path based extraction method. Corresponding centerline positions are used to determine the relative motion-vector fields from phase to phase. Finally, dense motion-vector fields are achieved by thin-plate-spline interpolation and used to perform a motion-corrected iterative reconstruction of a selected region of interest. The performance of the method is validated on five patients, showing the improved sharpness of cardiac motion-corrected gated iterative reconstructions compared to the results achieved by a classical gated iterative method. The results are also compared to known manual and fully automatic coronary artery motion estimation methods.

学科与关键词

关键词
Motion compensationCardiac motionComputed tomographyIterative reconstructionCoronary centerline extraction
相关
加载中…
  • A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography
    van Stevendaal, U.*; von Berg, J.; Lorenz, C.; Grass, M.Medical Physics, 2008, 35(7): 3239-3251.被引 36
  • Fully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac CT reconstruction
    Isola, Alfonso A.*; Grass, Michael; Niessen, Wiro J.Medical Physics, 2010, 37(3): 1093-1109.被引 55
  • Motion compensation in the region of the coronary arteries based on partial angle reconstructions from short-scan CT data
    Hahn, Juliane*; Bruder, Herbert; Rohkohl, Christopher; Allmendinger, Thomas; Stierstorfer, Karl; Flohr, Thomas; Kachelriess, MarcMedical Physics, 2017, 44(11): 5795-5813.被引 27
查看全部 →

发表信息

论文状态
公开发表
期刊
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS
发表日期
2012-04
卷期
第 36 卷, 第 3 期
页码
215-226
DOI
10.1016/j.compmedimag.2011.12.005
语言
ENGLISH
成果收录
SCIE
资助标注
European Community [MEST-CT-2005-020424]; Dutch Foundation for Scientific Research, NWO, STW

作者

  • I

    Isola, A. A. (通讯) (第一作者)

  • M

    Metz, C. T.

查看全部 6 位作者收起作者
  • S

    Schaap, M.

  • K

    Klein, S.

  • G

    Grass, M.

  • N

    Niessen, W. J.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417