摘要
Purpose: To qualitatively and quantitatively compare unenhanced ultra-low-dose chest computed tomography (ULD-CT) acquired at 80 kVp and 135 kVp. Materials and methods: Fifty-one patients referred for unenhanced chest CT were prospectively included. There were 29 men and 22 women, with a mean age of 64.7 +/- 11.6 (SD) years (range: 35-91 years) and a mean body mass index of 26.2 +/- 6.3 (SD) (range: 17-54.9). All patients underwent two different ULD-CT protocols (80 kVp-40 mA and 135 kVp-10 mA). Image quality of both ULD-CT examinations using a 5-level scale as well as assessability of 6 predetermined lung parenchyma lesions were blindly evaluated by three radiologists and compared using a logistic regression model. Image noise of the two protocols was compared with Wilcoxon signed-rank test. Results: The mean dose-length product at 80 kVp and at 135 kVp were 14.7 +/- 1.8 (SD) mGy.cm and 15.6 +/- 1.9 (SD) mGy.cm , respectively (P< 0.001). Image noise was significantly lower at 135 kVp (58.9 +/- 12.4) than at 80 kVp (74.7 +/- 14.5) (P <0.001). For all readers and for all examinations, the 135 kVp protocol yielded better image quality than 80 kVp protocol, with a mean qualitative score of 4.5 +/- 0.7 versus 3.9 +/- 0.8 (P < 0.001). The 135 kVp protocol was significantly more often of diagnostic quality than the 80 kvp protocol (92.3% versus 77.8%, respectively) (P<0.001) and was less prone to image quality deterioration in obese patients. Parenchymal lesions were never better depicted on the 80 kVp protocol than with the 135 kVp protocol. Conclusion: Unenhanced chest ULD-CT should be acquired at a high kilovoltage and low current, such as 135 kVp-10 mA, over a low kilovoltage and high current protocol.
学科与关键词
- Chest examination protocol with a reduced dose using a multi-slice spiral CTRehbock, B*; Hieckel, HGROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175(7): 963-966.被引 6
- Application of low-concentration contrast agents and low-tube-voltage computed tomography to chest enhancement examinations: A multicenter prospective studyMeng, Donghua; Cui, Xiaonan; Bai, Changsen; Yu, Zhongwen; Xin, Lei; Fu, Yufei; Wang, Sicong; Du, Yu; Gao, Zhipeng*; Ye, Zhaoxiang*SCIENCE PROGRESS, 2020, 103(1).被引 4
- Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient SizeDeak, Zsuzsanna; Maertz, Friedrich; Meurer, Felix; Notohamiprodjo, Susan; Mueck, Fabian; Geyer, Lucas L.; Reiser, Maximilian F.; Wirth, StefanJournal of Computer Assisted Tomography, 2017, 41(2): 254-262.被引 3