ScholarMate
客服热线:400-1616-289

Fatigue monitoring of coated steel belts by means of magnetic inspection

Liu, Sunqiang; Xia, Guisuo*; Wen, Zhihui; Cai, Qiwei; Liao, Mingliang
Science Citation Index Expanded
南昌航空大学

摘要

Coated steel belts (CSBs) are the primary load-bearing components of elevators. As a result, they may experience severe fatigue failure during their long-term service. In this study, a flexible fatigue fixture for CSBs is designed to simulate the CSB fatigue damage process for implementing a tensile fatigue test. The magnetic induction intensity signal on the surface of the CSB in a geomagnetic field environment is recorded using a high-precision weak magnetic sensor. Moreover, the CSB fatigue damage process is monitored online via the acquired magnetic induction intensity value. The fatigue test results indicate the following: the variation in the magnetic induction intensity signal curve can reflect the entire fatigue failure process when the CSB is under stress; the fatigue failure process of the steel wire inside the CSB does not occur smoothly as its progress occurs in stages; and the variation trend in the residual value between the magnetic induction intensity andfitting curves effectively indicates the degree of fatigue damage caused to the CSB.

关键词

coated steel belt magnetic induction intensity tensile fatigue online monitoring