Dual-Energy Low-keV or Single-Energy Low-kV CT for Endoleak Detection? A 6-Reader Study in an Aortic Aneurysm Phantom

Skawran, Stephan; Angst, Florian; Bluthgen, Christian; Eberhard, Matthias; Kalin, Pascal; Kobe, Adrian; Nagy, Daniel; Szucs-Farkas, Zsolt; Alkadhi, Hatem*; Euler, Andre
Investigative Radiology2020-1DOI: 10.1097/RLI.0000000000000606
15被引1阅读
引用收藏
分享

摘要

Objectives The aim of this study was to compare image quality, conspicuity, and endoleak detection between single-energy low-kV images (SEIs) and dual-energy low-keV virtual monoenergetic images (VMIs+) in computed tomography angiography of the aorta after endovascular repair. Materials and Methods An abdominal aortic aneurysm phantom simulating 36 endoleaks (2 densities; diameters: 2, 4, and 6 mm) in a medium- and large-sized patient was used. Each size was scanned using single-energy at 80 kVp (A) and 100 kVp (B), and dual-energy at 80/Sn150kVp for the medium (C) and 90/Sn150kVp for the large size (D). VMIs+ at 40 keV and 50 keV were reconstructed from protocols C and D. Radiation dose was 3 mGy for the medium and 6 mGy for the large size. Objective image quality and normalized noise power spectrum were determined. Subjective image quality, conspicuity, and sensitivity for endoleaks were independently assessed by 6 radiologists. Sensitivity was compared using Marascuilo procedure and Fisher exact test. Conspicuities were compared using Wilcoxon-matched pairs test, analysis of variance, and Tukey test. Results The contrast-to-noise-ratio of the aorta was significantly higher for VMI+ compared with SEI (P < 0.001). Noise power spectrum showed a higher noise magnitude and coarser texture in VMI+. Subjective image quality and overall conspicuity was lower for VMI+ compared with SEI (P < 0.05). Sensitivity for endoleaks was overall higher in the medium phantom for SEI (60.9% for A, 62.2% for B) compared with VMI+ (54.2% for C, 49.3% for D) with significant differences between protocols B and D (P < 0.05). In the large phantom, there was no significant difference in sensitivity among protocols (P = 0.79), with highest rates for protocols B (31.4%) and C (31.7%). Conclusions Our study indicates that low-keV VMI+ results in improved contrast-to-noise-ratio of the aorta, whereas noise properties, subjective image quality, conspicuity, and sensitivity for endoleaks were overall superior for SEI.

学科与关键词

关键词
multidetector computed tomographyaortic aneurysmabdominalendovascular proceduresendoleakphantomsimaging
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
Investigative Radiology
发表日期
2020-01
卷期
第 55 卷, 第 1 期
页码
45-52
DOI
10.1097/RLI.0000000000000606
语言
ENGLISH
期刊收录
NSL.SCIE
期刊等级
1区
成果收录
SCIE

作者

  • S

    Skawran, Stephan (第一作者)

  • A

    Angst, Florian

查看全部 10 位作者收起作者
  • B

    Bluthgen, Christian

  • E

    Eberhard, Matthias

  • K

    Kalin, Pascal

  • K

    Kobe, Adrian

  • N

    Nagy, Daniel

  • S

    Szucs-Farkas, Zsolt

  • A

    Alkadhi, Hatem (通讯)

  • E

    Euler, Andre

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417