摘要

A comprehensive validation of data acquired by different myocardial perfusion imaging (MPI) systems was performed to evaluate contrast, self-attenuation properties, and perfusion detection capability. An anthropomorphic phantom with a myocardial insert and perfusion defect was used to simulate 99mTc-tetrofosmin distribution. Different MPI systems were evaluated: a SPECT system with iterative reconstruction algorithms and resolution recovery (IRR) with/without scatter correction (SPECT-IRR-SC and SPECT-IRR), and a cardio-centric IQ SPECT/CT system with IRR, with/without scatter and attenuation corrections (IQ-IRR-SC-AC and IQ-IRR). The image quality was assessed through physical descriptors: the contrast between the left ventricular (LV) wall and LV inner chamber (CLV/LVIC), intrinsic contrast (IC), and net contrast (NC). CLV/LVIC was found to be superior for IQ-IRR-SC-AC. The IC results showed non-uniformity of the signal intensity in the LV wall for the SPECT systems. The lowest IC values were obtained for IQ-IRR-SC-AC, except for septal position, where an underestimation of the signal intensity was revealed. The NC was found to be the highest for IQ-IRR-SC-AC and SPECT-IRR-SC. Additionally, for IQ-IRR-SC-AC, the NC increased in posterior and septal positions compared to IQ-IRR, enabling better perfusion detection capability over short-axis images. IQ-IRR showed performances comparable to SPECT-IRR. The characterization and evaluation perfusion detection capability of the MPI systems enabled the investigation of the systems' performance and limitations.

学科与关键词

关键词
medical physicsSPECThybrid imagingmyocardial perfusion imagingimage qualityscatter correctionattenuation correctioniterative reconstruction with resolution recovery
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
Applied Sciences-Basel
发表日期
2024-06
卷期
第 14 卷, 第 12 期
页码
5283
DOI
10.3390/app14125283
语言
ENGLISH
成果收录
SCIE
资助标注
IAEA [CRO6021]; [UniRi-Iskusni-Prirod-23-8]

作者

  • D

    Dundara Debeljuh, Dea (第一作者)

  • M

    Matheoud, Roberta

查看全部 5 位作者收起作者
  • P

    Pribanic, Ivan

  • B

    Brambilla, Marco

  • J

    Jurkovic, Slaven (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417