摘要
The purpose of this article is to evaluate image quality and radiation dose of prospectively electrocardiogram (ECG)-triggered high-pitch coronary computed tomography angiography (CCTA) at 70 kVp and 30mL contrast medium. One hundred fifty patients with a heart rate <= 70 beats per minute (bpm) underwent CCTA using a second-generation dual-source computed tomography (CT) scanner and were randomized into 3 groups according to tube voltage and contrast medium volume (370 mg/mL iodine concentration) (100 kVp group, 100 kVp/60 mL, n = 55; 80 kVp group, 80 kVp/60 mL, n = 44; 70 kVp group, 70 kVp/30 mL, n = 51). Objective and subjective image quality along with the effect of heart rate (HR) and body mass index (BMI) was evaluated and compared between the groups. Radiation dose was estimated for each patient. CT attenuation and image noise were higher in the 80 and 70 kVp groups than in the 100 kVp group (all P< 0.001). Signal-tonoise ratios (SNRs) and contrast-to-noise ratios (CNRs) were lower in the 70 kVp group than in the 80 and 100 kVp groups (all P< 0.05). There was no difference for subjective image quality between the groups (P> 0.05). HR did not affect subjective image quality (all P> 0.05), while patients with BMI < 23 kg/m 2 had higher image quality than patients with BMI 3 23 kg/m 2 (P< 0.05). Compared with the 100 kVp group, the radiation dose of the 70 kVp group was reduced by 75%. In conclusion, prospectively ECG-triggered high-pitch 70 kVp/30mL CCTA can obtain diagnostic image quality with lower radiation dose in selected patients with BMI < 23 kg/m 2 compared with 80/100 kVp/60mL CCTA.
学科与关键词
- Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: An intraindividual comparison with sequential scanning at 120 kVp with 60 mL contrast agentWang, Wei; Zhao, Yan E.; Qi, Li; Li, Xie; Zhou, Chang Sheng; Zhang, Long Jiang*; Lu, Guang Ming*EUROPEAN JOURNAL OF RADIOLOGY, 2017, 90: 97-105.被引 22
- Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experienceZhang, Long Jiang*; Qi, Li; Wang, Jing; Tang, Chun Xiang; Zhou, Chang Sheng; Ji, Xue Man; Spearman, James V.; De Cecco, Carlo Nicola; Meinel, Felix G.; Schoepf, U. Joseph; Lu, Guang MingEuropean Radiology, 2014, 24(7): 1537-1546.被引 56
- Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocolChen, Yuhuan; Liu, Zhentang; Li, Michelle; Yu, Yong; Jia, Yongjun; Ma, Guangming; Hu, Zhijun; Wei, DongHong; Li, Dou; He, Taiping*European Radiology, 2019, 29(6): 3036-3043.被引 29