ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Longitudinal stability of MRI for mapping brain change using tensor-based morphometry

Leow, Alex D.; Klunder, Andrea D.; Jack, Clifford R., Jr.; Toga, Arthur W.; Dale, Anders M.; Bernstein, Matt A.; Britson, Paula J.; Gunter, Jefftey L.; Ward, Chadwick P.; Whitwell, Jennifer L.; Borowski, Bret J.; Fleisher, Adam S.; Fox, Nick C.; Harvey, Danielle; Kornak, John; Schuff, Norbert; Studholme, Colin; Alexander, Gene E.; Weiner, Michael W.; Thompson, Paul M.*
NeuroImage2006-6DOI: 10.1016/j.neuroimage.2005.12.013
174被引2阅读
引用收藏
分享

摘要

Measures of brain change can be computed from sequential MRI scans, providing valuable information on disease progression, e.g., for patient monitoring and drug trials. Tensor-based morphometry (TBM) creates maps of these brain changes, visualizing the 3D profile and rates of tissue growth or atrophy, but its sensitivity depends on the contrast and geometric stability of the images. As part of the Alzheimer's Disease Neuroimaging Initiative (ADNI), 17 normal elderly subjects were scanned twice (at a 2-week interval) with several 3D 1.5 T MRI pulse sequences: high and low flip angle SPGR/FLASH (from which Synthetic T1 images were generated), MP-RAGE, IR-SPGR (N = 10) and MEDIC (N = 7) scans. For each subject and scan type, a 3D deformation map aligned baseline and follow-up scans, computed with a nonlinear, inverse-consistent elastic registration algorithm. Voxelwise statistics, in ICBM stereotaxic space, visualized the profile of mean absolute change and its cross-subject variance; these maps were then compared using permutation testing. Image stability depended on: (1) the pulse sequence; (2) the transmit/receive coil type (birdcage versus phased array); (3) spatial distortion corrections (using MEDIC sequence information); (4) B1-ield intensity inhomogeneity correction (using N3). SPGR/FLASH images acquired using a birdcage coil had least overall deviation. N3 correction reduced coil type and pulse sequence differences and improved scan reproducibility, except for Synthetic T1 images (which were intrinsically corrected for B1-inhomogeneity). No strong evidence favored B0 correction. Although SPGR/FLASH images showed least deviation here, pulse sequence selection for the ADN1 project was based on multiple additional image analyses, to be reported elsewhere.

学科与关键词

关键词
SERIAL MRIDISEASE PROGRESSIONREGISTRATIONATROPHYIMAGESSEGMENTATIONFRAMEWORKATLASVOXELDEFORMATIONS
相关
加载中…
  • Comparing registration methods for mapping brain change using tensor-based morphometry
    Yanovsky, Igor*; Leow, Alex D.; Lee, Suh; Osher, Stanley J.; Thompson, Paul M.Medical Image Analysis, 2009, 13(5): 679-700.被引 44
  • Accurate measurement of brain changes in longitudinal MRI scans using tensor-based morphometry
    Hua, Xue; Gutman, Boris; Boyle, Christina P.; Rajagopalan, Priya; Leow, Alex D.; Yanovsky, Igor; Kumar, Anand R.; Toga, Arthur W.; Jack, Clifford R., Jr.; Schuff, Norbert; Alexander, Gene E.; Chen, Kewei; Reiman, Eric M.; Weiner, Michael W.; Thompson, Paul M.*NeuroImage, 2011, 57(1): 5-14.被引 64
  • Unbiased tensor-based morphometry: Improved robustness and sample size estimates for Alzheimer's disease clinical trials
    Hua, Xue; Hibar, Derrek P.; Ching, Christopher R. K.; Boyle, Christina P.; Rajagopalan, Priya; Gutman, Boris A.; Leow, Alex D.; Toga, Arthur W.; Jack, Clifford R., Jr.; Harvey, Danielle; Weiner, Michael W.; Thompson, Paul M.*NeuroImage, 2013, 66: 648-661.被引 91
查看全部 →

发表信息

论文状态
公开发表
期刊
NeuroImage
发表日期
2006-06
卷期
第 31 卷, 第 2 期
页码
627-640
DOI
10.1016/j.neuroimage.2005.12.013
语言
ENGLISH
成果收录
SCIE
资助标注
MRC [G116/143] Funding Source: UKRI; Medical Research Council [G116/143] Funding Source: Medline; NCRR NIH HHS [R21 RR019771, RR019771] Funding Source: Medline; NIA NIH HHS [R01 AG010897, U19 AG010483, U01 AG024904, P50 AG016570, AG016570] Funding Source: Medline; NIBIB NIH HHS [EB01651] Funding Source: Medline; NLM NIH HHS [R01 LM005639, LM05639] Funding Source: Medline

作者

  • L

    Leow, Alex D. (第一作者)

  • K

    Klunder, Andrea D.

查看全部 20 位作者收起作者
  • J

    Jack, Clifford R., Jr.

  • T

    Toga, Arthur W.

  • D

    Dale, Anders M.

  • B

    Bernstein, Matt A.

  • B

    Britson, Paula J.

  • G

    Gunter, Jefftey L.

  • W

    Ward, Chadwick P.

  • W

    Whitwell, Jennifer L.

  • B

    Borowski, Bret J.

  • F

    Fleisher, Adam S.

  • F

    Fox, Nick C.

  • H

    Harvey, Danielle

  • K

    Kornak, John

  • S

    Schuff, Norbert

  • S

    Studholme, Colin

  • A

    Alexander, Gene E.

  • W

    Weiner, Michael W.

  • T

    Thompson, Paul M. (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417