摘要
To evaluate the diagnostic accuracy of sub-milliSievert (mSv) coronary CT angiography (cCTA) using prospectively ECG-triggered high-pitch spiral CT acquisition combined with iterative image reconstruction. Forty consecutive patients (52.9 +/- 8.7 years; 30 men) underwent dual-source cCTA using prospectively ECG-triggered high-pitch spiral acquisition. The tube current-time product was set to 50 % of standard-of-care CT examinations. Images were reconstructed with sinogram-affirmed iterative reconstruction. Image quality was scored and diagnostic performance for detection of a parts per thousand yen50 % stenosis was determined with catheter coronary angiography (CCA) as the reference standard. CT was successfully performed in all 40 patients. Of the 601 assessable coronary segments, 543 (90.3 %) had diagnostic image quality. Per-patient sensitivity for detection of a parts per thousand yen50 % stenosis was 95.7 % [95 % confidence interval (CI), 76.0-99.8 %] and specificity was 94.1 % (95 % CI, 69.2-99.7 %). Per-vessel sensitivity was 89.5 % (95 % CI, 77.8-95.6 %) with 93.2 % specificity (95 % CI, 86.0-97.0 %). The area under the receiver-operating characteristic curve on per-patient and per-vessel levels was 0.949 and 0.913. Mean effective dose was 0.58 +/- 0.17 mSv. Mean size-specific dose estimate was 3.14 +/- 1.15 mGy. High-pitch prospectively ECG-triggered cCTA combined with iterative image reconstruction provides high diagnostic accuracy with a radiation dose below 1 mSv for detection of coronary artery stenosis. aEuro cent Cardiac CT with sub-milliSievert radiation dose is feasible in many patients aEuro cent High-pitch spiral CT acquisition with iterative reconstruction detects coronary stenosis accurately. aEuro cent Iterative reconstruction increases who can benefit from low-radiation cardiac CT.
学科与关键词
- Accuracy of high-pitch prospectively ECG-triggering CT coronary angiography for assessment of stenosis in 103 patients: Comparison with invasive coronary angiographyHu, X. H.; Zheng, W. L.*; Wang, D.; Xie, S. S.; Wu, R.; Zhang, S. Z.Clinical Radiology, 2012, 67(11): 1083-1088.被引 10
- Accuracy of Coronary CT Angiography Using a Submillisievert Fraction of Radiation Exposure Comparison With Invasive Coronary AngiographyStehli, Julia*; Fuchs, Tobias A.; Bull, Sacha; Clerc, Olivier F.; Possner, Mathias; Buechel, Ronny R.; Gaemperli, Oliver; Kaufmann, Philipp A.Journal of the American College of Cardiology, 2014, 64(8): 772-780.被引 70
- Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: An intraindividual comparison with sequential scanning at 120 kVp with 60 mL contrast agentWang, Wei; Zhao, Yan E.; Qi, Li; Li, Xie; Zhou, Chang Sheng; Zhang, Long Jiang*; Lu, Guang Ming*EUROPEAN JOURNAL OF RADIOLOGY, 2017, 90: 97-105.被引 22