Objective: CT coronary artery calcium scoring (CACS) is additive to traditional risk factors for predicting future cardiac events but is associated with relatively high radiation doses. We assessed the feasibility of CACS radiation dose reduction using a lower tube current and iterative reconstruction (IR). Methods: Artificial noise was added to the raw data from 27 CACS studies from patients who were symptomatic to simulate lower tube current scanning (75, 50 and 25% original current). All studies were performed on the same CT scanner at 120 kVp. Data were reconstructed using filtered back projection [Quantum Denoising Software (QDS1)] and IR [adaptive iterative dose reduction three dimensional mild, standard and strong]. Agatston scores were independently measured by two readers. CACS percentile risk scores were calculated. Results: At 75, 50 and 25% tube currents, all adaptive iterative dose reduction (AIDR) reconstructions decreased image noise relative to QDS1 (p < 0.05). All AIDR reconstructions resulted in small reductions in Agatston score relative to QDS1 at the standard tube current (p, 0.05). Agatston scores increased with QDS1 at 75, 50 and 25% tube current (p, 0.05), whereas no significant change was observed with AIDR mild at any tested tube current. No difference in the percentile risk score with AIDR mild at any tube current occurred compared with QDS1 at standard tube current (p. 0.05). Interobserver agreement for AIDR mild remained excellent even at 25% tube current (intraclass correlation coefficient 0.997). Conclusion: Up to 75% reduction in CACS tube current is feasible using AIDR mild. Advances in knowledge: AIDR mild IR permits low tube current CACS whilst maintaining excellent intraobserver and interobserver variability and without altering risk classification.
学科与关键词
- Prospective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CTChoi, Andrew D.; Leifer, Eric S.; Yu, Jeannie; Shanbhag, Sujata M.; Bronson, Kathie; Arai, Andrew E.; Chen, Marcus Y.*Journal of Cardiovascular Computed Tomography, 2016, 10(5): 359-363.被引 27
- Dose reduction techniques in coronary calcium scoring: The effect of iterative reconstruction combined with low tube voltage on calcium scores in a thoracic phantomVonder, Marleen*; Pelgrim, Gert Jan; Meyer, Mathias; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, RozemarijnEUROPEAN JOURNAL OF RADIOLOGY, 2017, 93: 229-235.被引 10
- The influence of Iterative Reconstruction on Coronary Artery Calcium Scoring-Phantom and Clinical StudiesOda, Seitaro*; Utsunomiya, Daisuke; Nakaura, Takeshi; Funama, Yoshinori; Yuki, Hideaki; Kidoh, Masafumi; Hirata, Kenichiro; Taguchi, Narumi; Honda, Keiichi; Takaoka, Hiroko; Iyama, Yuji; Katahira, Kazuhiro; Noda, Katsuo; Oshima, Shuichi; Tokuyasu, Shinichi; Yamashita, YasuyukiACADEMIC RADIOLOGY, 2017, 24(3): 295-301.被引 8