Standard dose versus low-dose abdominal and pelvic CT: Comparison between filtered back projection versus adaptive iterative dose reduction 3D

Gervaise, A.*; Osemont, B.; Louis, M.; Lecocq, S.; Teixeira, P.; Blum, A.
Diagnostic and Interventional Imaging2014-1DOI: 10.1016/j.diii.2013.05.005
44被引4阅读
引用收藏
分享

摘要

Purpose: To compare the dose and image quality of a standard dose abdominal and pelvic CT with Filtered Back Projection (FBP) to low-dose CT with Adaptive Iterative Dose Reduction 3D (AIDR 3D). Materials and methods: We retrospectively examined the images of 21 patients in the portal phase of an abdominal and pelvic CT scan before and after implementation of AIDR 3D iterative reconstruction. The acquisition length, dose and evaluations of the image quality were compared between standard dose FBP images and low-dose images reconstructed with AIDR 3D and FBP using the Wilcoxon test. Results: The mean acquisition length was similar for both CT scans. There was a significant dose reduction of 49.5% with low-dose CT compared to standard dose CT (mean DLP of 451 mGy.cm versus 892 mGy.cm, P < 0.001). There were no differences in image quality scores between standard dose FBP and low-dose AIDR 3D images (4.6 +/- 0.6 versus 4.4 +/- 0.6 respectively, P = 0.147). Conclusion: AIDR 3D iterative reconstruction enables a significant reduction in dose of 49.5% to be achieved with abdominal CT scan compared to FBP, whilst maintaining equivalent image quality.

学科与关键词

关键词
Multidetector CTDose reductionImage qualityIterative reconstructionAbdominal and pelvic CT
相关
加载中…
  • Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection
    Matsuki, Mitsuru*; Murakami, Takamichi; Juri, Hiroshi; Yoshikawa, Shushi; Narumi, YoshifumiActa Radiologica, 2013, 54(8): 869-875.被引 34
  • Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm: A Phantom Study
    Onishi, Hiromitsu*; Kockelkoren, Remko; Kim, Tonsok; Hori, Masatoshi; Nakamoto, Atsushi; Tsuboyama, Takahiro; Sakane, Makoto; Tatsumi, Mitsuaki; Uranishi, Ayumi; Tanaka, Toshiya; Taniguchi, Akira; Enchi, Yukihiro; Satoh, Kazuhiko; Tomiyama, NoriyukiJournal of Computer Assisted Tomography, 2015, 39(4): 629-634.被引 6
  • Influence of the adaptive iterative dose reduction 3D algorithm on the detectability of low-contrast lesions and radiation dose repeatability in abdominal computed tomography: a phantom study
    Yoon, Jeong Hee; Lee, Jeong Min*; Hur, Bo Yun; Baek, Jeehyun; Shim, Hackjoon; Han, Joon Koo; Choi, Byung IhnAbdominal Imaging, 2015, 40(6): 1843-1852.被引 8
查看全部 →

发表信息

论文状态
公开发表
期刊
Diagnostic and Interventional Imaging
发表日期
2014-01
卷期
第 95 卷, 第 1 期
页码
47-53
DOI
10.1016/j.diii.2013.05.005
成果收录
SCIE

作者

  • G

    Gervaise, A. (通讯) (第一作者)

  • O

    Osemont, B.

查看全部 6 位作者收起作者
  • L

    Louis, M.

  • L

    Lecocq, S.

  • T

    Teixeira, P.

  • B

    Blum, A.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417