ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Prior CT Improves Deep Learning for Malignancy Risk Estimation of Screening-detected Pulmonary Nodules

Venkadesh, Kiran Vaidhya; Aleef, Tajwar Abrar; Scholten, Ernst T.; Saghir, Zaigham; Silva, Mario; Sverzellati, Nicola; Pastorino, Ugo; van Ginneken, Bram; Prokop, Mathias; Jacobs, Colin*
RADIOLOGY2023-8DOI: 10.1148/radiol.223308
10被引14阅读
引用收藏
分享

摘要

Background: Prior chest CT provides valuable temporal information (eg, changes in nodule size or appearance) to accurately estimate malignancy risk.Purpose: To develop a deep learning (DL) algorithm that uses a current and prior low-dose CT examination to estimate 3-year malignancy risk of pulmonary nodules.Materials and Methods: In this retrospective study, the algorithm was trained using National Lung Screening Trial data (collected from 2002 to 2004), wherein patients were imaged at most 2 years apart, and evaluated with two external test sets from the Danish Lung Cancer Screening Trial (DLCST) and the Multicentric Italian Lung Detection Trial (MILD), collected in 2004-2010 and 2005-2014, respectively. Performance was evaluated using area under the receiver operating characteristic curve (AUC) on cancer-enriched subsets with size-matched benign nodules imaged 1 and 2 years apart from DLCST and MILD, respectively. The algorithm was compared with a validated DL algorithm that only processed a single CT examination and the Pan-Canadian Early Lung Cancer Detection Study (PanCan) model.Results: The training set included 10 508 nodules (422 malignant) in 4902 trial participants (mean age, 64 years +/- 5 [SD]; 2778 men). The size-matched external test sets included 129 nodules (43 malignant) and 126 nodules (42 malignant). The algorithm achieved AUCs of 0.91 (95% CI: 0.85, 0.97) and 0.94 (95% CI: 0.89, 0.98). It significantly outperformed the DL algorithm that only processed a single CT examination (AUC, 0.85 [95% CI: 0.78, 0.92; P = .002]; and AUC, 0.89 [95% CI: 0.84, 0.95; P = .01]) and the PanCan model (AUC, 0.64 [95% CI: 0.53, 0.74; P < .001]; and AUC, 0.63 [95% CI: 0.52, 0.74; P < .001]). Conclusion: A DL algorithm using current and prior low-dose CT examinations was more effective at estimating 3-year malignancy risk of pulmonary nodules than established models that only use a single CT examination.

学科与关键词

关键词
LUNG-CANCER RISKLOW-DOSE CTARTIFICIAL-INTELLIGENCETRIALPREDICTIONPROBABILITYMORTALITY
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
RADIOLOGY
发表日期
2023-08
卷期
第 308 卷, 第 2 期
页码
e223308
DOI
10.1148/radiol.223308
语言
ENGLISH
成果收录
SCIE

作者

  • V

    Venkadesh, Kiran Vaidhya (第一作者)

  • A

    Aleef, Tajwar Abrar

查看全部 10 位作者收起作者
  • S

    Scholten, Ernst T.

  • S

    Saghir, Zaigham

  • S

    Silva, Mario

  • S

    Sverzellati, Nicola

  • P

    Pastorino, Ugo

  • v

    van Ginneken, Bram

  • P

    Prokop, Mathias

  • J

    Jacobs, Colin (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417