Diagnostic Performance of Single-Photon Emission Computed Tomography/Computed Tomography in Aseptic Loosening: A Systematic Review and Meta-Analysis

Peng, Zhan*; Jia, Yukun; Li, Jin; Wang, Guangye*南方医科大学
JOURNAL OF ARTHROPLASTY2021-12DOI: 10.1016/j.arth.2021.06.018
3被引8阅读
引用收藏
分享

摘要

Background: The aim of this study is to evaluate the diagnostic value and clinical applicability of single photon emission computed tomography/computed tomography (SPECT/CT) in aseptic loosening (AL) of prostheses by meta-analysis. Method: Literature on the diagnostic value of SPECT/CT in AL of prostheses was obtained by computer and manual review. The quality of the included studies was evaluated according to the Quality Assessment Diagnostic Accuracy Studies 2. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and other indicators were calculated, and a forest map and summary receiver operating characteristic were drawn to calculate the area under the curve. Meta regression analysis was performed to identify the sources of heterogeneity and corresponding subgroup analysis was performed. A Fagan plot, likelihood ratio point plot, and Deek's funnel plot were drawn and analyzed. Results: A total of 15 studies were included. The meta-analysis results showed that the pooled sensitivity and specificity of SPECT/CT for the diagnosis of aseptic prosthetic loosening were 0.94, 95% confidence interval [CI] (0.90-0.96) and 0.89, 95% CI (0.78-0.95), respectively while the pooled positive likelihood ratio and pooled negative likelihood ratio were 8.65, 95% CI (4.18-17.90) and 0.07, 95% CI (0.04-0.11), respectively. The pooled diagnostic odds ratio was 130.36, 95% CI (45.18-376.19), and the area under the curve was 0.97, 95% CI (0.95-0.98). Conclusion: As a diagnostic method for AL, SPECT/CT has high diagnostic sensitivity and specificity as well as high diagnostic efficiency. It has good clinical application value and should be a primary choice in the diagnosis of AL after joint replacement.

学科与关键词

关键词
aseptic looseningSPECTCTdiagnostic valuemeta-analysisprothesis replacement
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
JOURNAL OF ARTHROPLASTY
发表日期
2021-12
卷期
第 36 卷, 第 12 期
页码
4003-+
DOI
10.1016/j.arth.2021.06.018
语言
ENGLISH
期刊收录
NSL
期刊等级
1区
成果收录
SCIE

作者

  • P

    Peng, Zhan (通讯) (第一作者)

    southern med univ · 2

  • J

    Jia, Yukun

    southern med univ · 2

查看全部 4 位作者收起作者
  • L

    Li, Jin

    southern med univ · 2

  • W

    Wang, Guangye (通讯)

    southern med univ · 2

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417