Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis

Dwyer, Michael G.*; Silva, Diego; Bergsland, Niels; Horakova, Dana; Ramasamy, Deepa; Durfee, Jaqueline; Vaneckova, Manuela; Havrdova, Eva; Zivadinov, Robert
NeuroImage-Clinical2017DOI: 10.1016/j.nicl.2017.06.022
50被引2阅读
引用收藏
分享

摘要

Background: There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. Objectives: To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality T2-FLAIR images in MS patients. Methods: A real-world dataset from 109 MS patients from 62 MRI scanners was used to develop a lateral ventricular volume (LVV) algorithm with a longitudinal Jacobian-based extension, called NeuroSTREAM. Goldstandard LVV was calculated on high-resolution T1 1 mm, while NeuroSTREAM LVV was obtained on lowresolution T2-FLAIR 3 mm thick images. Scan-rescan reliability was assessed in 5 subjects. The variability of LVV measurement at different field strengths was tested in 76 healthy controls and 125 MS patients who obtained both 1.5T and 3T scans in 72 hours. Clinical validation of algorithm was performed in 176 MS patients who obtained serial yearly MRI 1.5T scans for 10 years. Results: Correlation between gold-standard high-resolution T1 LVV and low-resolution T2-FLAIR LVV was r= 0.99, p < 0.001 and the scan-rescan coefficient of variation was 0.84%. Correlation between low-resolution T2-FLAIR LVV on 1.5T and 3T was r= 0.99, p < 0.001 and the scan-rescan coefficient of variation was 2.69% cross-sectionally and 2.08% via Jacobian integration. NeuroSTREAM showed comparable effect size (d = 0.39-0.71) in separating MS patients with and without confirmed disability progression, compared to SIENA and VIENA. Conclusions: Brain atrophy measurement on clinical quality T2-FLAIR scans is feasible, accurate, reliable, and relates to clinical outcomes.

学科与关键词

关键词
Brain atrophyVentricular volumeAutomated measurementMultiple sclerosis
相关
加载中…
  • Reliability of Longitudinal Brain Volume Loss Measurements between 2 Sites in Patients with Multiple Sclerosis: Comparison of 7 Quantification Techniques
    Durand-Dubief, F.*; Belaroussi, B.; Armspach, J. P.; Dufour, M.; Roggerone, S.; Vukusic, S.; Hannoun, S.; Sappey-Marinier, D.; Confavreux, C.; Cotton, F.AJNR. American journal of neuroradiology, 2012, 33(10): 1918-1924.被引 70
  • Intra-and interscanner variability of magnetic resonance imaging based volumetry in multiple sclerosis
    Biberacher, Viola*; Schmidt, Paul; Keshavan, Anisha; Boucard, Christine C.; Righart, Ruthger; Saemann, Philipp; Preibisch, Christine; Froebel, Daniel; Aly, Lilian; Hemmer, Bernhard; Zimmer, Claus; Henry, Roland G.; Muehlau, MarkNeuroImage, 2016, 142: 479-488.被引 68
  • Whole-brain atrophy assessed by proportional- versus registration-based pipelines from 3T MRI in multiple sclerosis
    Hemond, Christopher C.; Chu, Renxin; Tummala, Subhash; Tauhid, Shahamat; Healy, Brian C.; Bakshi, Rohit*Brain and Behavior, 2018, 8(8): e01068.被引 8
查看全部 →

发表信息

论文状态
公开发表
期刊
NeuroImage-Clinical
发表日期
2017
卷期
第 15 卷
页码
769-779
DOI
10.1016/j.nicl.2017.06.022
语言
ENGLISH
期刊等级
Q1
成果收录
SCIE

作者

  • D

    Dwyer, Michael G. (通讯) (第一作者)

  • S

    Silva, Diego

查看全部 9 位作者收起作者
  • B

    Bergsland, Niels

  • H

    Horakova, Dana

  • R

    Ramasamy, Deepa

  • D

    Durfee, Jaqueline

  • V

    Vaneckova, Manuela

  • H

    Havrdova, Eva

  • Z

    Zivadinov, Robert

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417