Design and platform testing of the compact torus central fueling device for the EAST tokamak

Kong, Defeng; Zhuang, Ge; Lan, Tao*; Zhang, Shoubiao*; Ye, Yang; Dong, Qilong; Chen, Chen; Wu, Jie; Zhang, Sen; Zhao, Zhihao; Meng, Fanwei; Zhang, Xiaohui; Huang, Yanqing; Wen, Fei; Zi, Pengfei; LI, Lei; Hu, Guanghai; Song, Yuntao
Science Citation Index Expanded
衡阳师范学院; 中国科学院

摘要

Compact torus (CT) injection is a highly promising technique for the central fueling of future reactor-grade fusion devices since it features extremely high injection velocity and relatively high plasma mass. Recently, a CT injector for the EAST tokamak, EAST-CTI, was developed and platform-tested. In the first round of experiments conducted with low parameter settings, the maximum velocity and mass of the CT plasma were 150 km center dot s(-1) and 90 mu g, respectively. However, the parameters obtained by EAST-CTI were still very low and were far from the requirements of a device such as EAST that has a strong magnetic field. In future, we plan to solve the spark problem that EAST-CTI currently encounters (that mainly hinders the further development of experiments) through engineering methods, and use greater power to obtain a more stable and suitable CT plasma for EAST.

关键词

compact torus (CT) central fueling EAST-CTI EAST tokamak