Cardiac Motion Correction for Helical CT Scan With an Ordinary Pitch

Kim, Seungeon; Chang, Yongjin; Ra, Jong Beom*
IEEE Transactions on Medical Imaging2018-7DOI: 10.1109/TMI.2018.2817594
13被引5阅读
引用收藏
分享

摘要

Cardiac X-ray computed tomography (CT) imaging is still challenging due to the cardiac motion during CT scanning, which leads to the presence of motion artifacts in the reconstructed image. In response, many cardiac X-ray CT imaging algorithms have been proposed, based on motion estimation (ME) and motion compensation (MC), to improve the image quality by alleviating the motion artifacts in the reconstructed image. However, these ME/MC algorithms are mainly based on an axial scan or a low-pitch helical scan. In this paper, we propose a ME/MC-based cardiac imaging algorithm for the data set acquired from a helical scan with an ordinary pitch of around 1.0 so as to obtain the whole cardiac image within a single scan of short time without ECG gating. In the proposed algorithm, a sequence of partial angle reconstructed (PAR) images is generated by using consecutive parts of the sinogram, each of which has a small angular span. Subsequently, an initial 4-D motion vector field (MVF) is obtained using multiple pairs of conjugate PAR images. The 4-D MVF is then refined based on an image quality metric so as to improve the quality of the motion-compensated image. Finally, a time-resolved cardiac image is obtained by performing motion-compensated image reconstruction by using the refined 4-DMVF. Using digital XCAT phantom data sets and a human data set commonly obtained via a helical scan with a pitch of 1.0, we demonstrate that the proposed algorithm significantly improves the image quality by alleviating motion artifacts.

学科与关键词

关键词
Cardiac motion estimation and compensationcardiac X-ray computed tomography (CT)coronary artery imaginghelical CT scanpartial angle reconstruction
相关
加载中…
  • A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography
    van Stevendaal, U.*; von Berg, J.; Lorenz, C.; Grass, M.Medical Physics, 2008, 35(7): 3239-3251.被引 36
  • Head Motion Correction Based on Filtered Backprojection in Helical CT Scanning
    Jang, Seokhwan; Kim, Seungeon; Kim, Mina; Son, Kihong; Lee, Kyoung-Yong; Ra, Jong Beom*IEEE Transactions on Medical Imaging, 2020, 39(5): 1636-1645.被引 7
  • Motion compensation in the region of the coronary arteries based on partial angle reconstructions from short-scan CT data
    Hahn, Juliane*; Bruder, Herbert; Rohkohl, Christopher; Allmendinger, Thomas; Stierstorfer, Karl; Flohr, Thomas; Kachelriess, MarcMedical Physics, 2017, 44(11): 5795-5813.被引 27
查看全部 →

发表信息

论文状态
公开发表
期刊
IEEE Transactions on Medical Imaging
发表日期
2018-07
卷期
第 37 卷, 第 7 期
页码
1587-1596
DOI
10.1109/TMI.2018.2817594
语言
ENGLISH
期刊等级
Q1
成果收录
SCIE
资助标注
Samsung Electronics

作者

  • K

    Kim, Seungeon (第一作者)

  • C

    Chang, Yongjin

查看全部 3 位作者收起作者
  • R

    Ra, Jong Beom (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417