ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Observer Performance with Varying Radiation Dose and Reconstruction Methods for Detection of Hepatic Metastases

Fletcher, Joel G.*; Fidler, Jeff L.; Venkatesh, Sudhakar K.; Hough, David M.; Takahashi, Naoki; Yu, Lifeng; Johnson, Matthew; Leng, Shuai; Holmes, David R., III; Carter, Rickey; McCollough, Cynthia H.
RADIOLOGY2018-11DOI: 10.1148/radiol.2018180125
46被引2阅读
引用收藏
分享

摘要

Purpose: To estimate the ability of lower dose levels and iterative reconstruction (IR) to display hepatic metastases that can be detected by radiologists. Materials and Methods: Projection data from 83 contrast agent-enhanced CT examinations were collected. Metastases were defined by histopathologic analysis or progression and regression. Lower radiation dose configurations were reconstructed at five dose levels with filtered back projection (FBP) and IR (automatic exposure control settings: 80, 100, 120, 160, and 200 quality reference mAs [QRM]). Three abdominal radiologists circumscribed metastases, indicating confidence (confidence range, 0-100) and image quality. Noninferiority was assessed by using jackknife alternative free-response receiver operating characteristic (JAFROC) analysis (noninferiority limit, 20.10) and reader agreement rules, which required identification of metastases identified at routine dose, and no nonlesion localizations in patients negative for metastases, in 71 or more patient CT examinations (of 83), for each configuration. Results: There were 123 hepatic metastases (mean size, 1.4 cm; median volume CT dose index and size-specific dose estimate, 11.0 and 13.4 mGy, respectively). By using JAFROC figure of merit, 100 QRM FBP did not meet noninferiority criteria and had estimated performance difference from routine dose of -0.08 (95% confidence interval: -0.11, -0.04). Preset reader agreement rules were not met for 100 QRM IR or 80 QRM IR, but were met for doses 120 QRM or higher (ie, size-specific dose estimate >= 8.0 mGy). IR improved image quality (P < .05) but not reader performance. Other than 160 QRM IR, lower dose levels were associated with reduced confidence in metastasis detection (P < .001). Conclusion: For detection of hepatic metastases by using contrast-enhanced CT, dose levels that corresponded to 120 quality reference mAs (size-specific dose estimate, 8.0 mGy) and higher performed similarly to 200 quality reference mAs with filtered back projection.

学科与关键词

关键词
FILTERED BACK-PROJECTIONITERATIVE RECONSTRUCTIONLIVER-LESIONSLOW-CONTRASTIMAGE NOISECTREDUCTIONPHANTOMDETECTABILITYRESOLUTION
相关
加载中…
  • Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CT
    Jensen, Corey T.*; Wagner-Bartak, Nicolaus A.; Vu, Lan N.; Liu, Xinnzing; Raval, Bharat; Martinez, David; Wei, Wei; Cheng, Yuan; Samei, Ehsan; Gupta, ShivaRADIOLOGY, 2019, 290(2): 400-409.被引 73
  • Estimwtion of Observer Performance for Reduced Radiation Dose Lavels in CT: Eliminating Reduced Dose Levels That Are Too Low Is the First Step
    Fletcher, Joel G.*; Yu, Lifeng; Fidler, Jeff L.; Levin, David L.; DeLone, David R.; Hough, David M.; Takahashi, Naoki; Venkatesh, Sudhakar K.; Sykes, Anne-Marie G.; White, Darin; Lindell, Rebecca M.; Kotsenas, Amy L.; Campeau, Norbert G.; Lehman, Vance T.; Bartley, Adam C.; Leng, Shuai; Holmes, David R., III; Toledano, Alicia Y.; Carter, Rickey E.; McCollough, Cynthia H.ACADEMIC RADIOLOGY, 2017, 24(7): 876-890.被引 42
  • Is it possible to use low-dose deep learning reconstruction for the detection of liver metastases on CT routinely?
    Lyu, Peijie; Liu, Nana; Harrawood, Brian; Solomon, Justin; Wang, Huixia; Chen, Yan; Rigiroli, Francesca; Ding, Yuqin; Schwartz, Fides Regina; Jiang, Hanyu; Lowry, Carolyn; Wang, Luotong; Samei, Ehsan; Gao, Jianbo*; Marin, DanieleEuropean Radiology, 2023, 33(3): 1629-1640.被引 23
查看全部 →

发表信息

论文状态
公开发表
期刊
RADIOLOGY
发表日期
2018-11
卷期
第 289 卷, 第 2 期
页码
455-464
DOI
10.1148/radiol.2018180125
语言
ENGLISH
期刊等级
Q1
成果收录
SCIE
资助标注
National Institutes of Health [EB017095, EB017185]

作者

  • F

    Fletcher, Joel G. (通讯) (第一作者)

  • F

    Fidler, Jeff L.

查看全部 11 位作者收起作者
  • V

    Venkatesh, Sudhakar K.

  • H

    Hough, David M.

  • T

    Takahashi, Naoki

  • Y

    Yu, Lifeng

  • J

    Johnson, Matthew

  • L

    Leng, Shuai

  • H

    Holmes, David R., III

  • C

    Carter, Rickey

  • M

    McCollough, Cynthia H.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417