摘要
Objective: The objective of this study was to compare the radiation exposure and image quality of contrast-enhanced multidetector computed tomography angiography (CTA) and computed tomography cholangiography (CTC) performed for living liver donor evaluation using 80 and 120 kVp. Methods: Ninety-three potential liver donors who underwent pre-operative contrast-enhanced 64 multidetector CTA and CTC were retrospectively divided into 2 groups: at 80 and at 120 kVp. An institutional review board waiver was obtained. Signal-to-noise ratio and contrast-tonoise ratio of the hepatic artery and common bile duct were obtained. The dose-length product was recorded. Image quality and visibility of hepatic artery and biliary tract anatomy were evaluated. Mann-Whitney U test was used for statistical evaluation. Results: Mean hepatic artery/common bile duct signal-to-noise ratio was 28.9/28.6 (SD, 14.2/10.0) at 80 kVp and 27.6/25.8 (SD, 8.0/6.2) at 120 kVp (P = 0.61/0.099). Mean hepatic artery/common bile duct contrast-to-noise ratio was 24.8/23.3 (SD, 12.9/8.6) at 80 kVp and 22.2/19.3 (SD, 7.7/5.0) at 120 kVp (P = 0.76/0.005). Mean CTA/CTC dose-length product was 279/281 (SD, 42/52) mGy-cm at 80 kVp and 407/451 (SD, 208/243) mGy-cm at 120 kVp (P = 0.026/0.002). Computed tomography cholangiography image quality and visibility of biliary tract anatomy were not significantly different at 80 versus 120 kVp (all P > 0.13). Computed tomography angiography image quality was significantly lower (P < 0.01), and the noise scores significantly higher (P < 0.01) at 80 versus 120 kVp, but diagnostic. Conclusions: Contrast-enhanced CTA and CTC performed at 80 kVp result in comparable image quality and anatomical evaluation with reduced radiation exposure when compared with 120 kVp.
学科与关键词
- CT Angiography in Potential Living Kidney Donors: 80 kVp Versus 120 kVpDavarpanah, Amir H.*; Pahade, Jay K.; Cornfeld, Dan; Ghita, Monica; Kulkarni, Sanjay; Israel, Gary M.American Journal of Roentgenology, 2013, 201(5): W753-W760.被引 12
- Clinical impact of low tube voltage computed tomography during hepatic arteriography with low iodine to detect hepatocellular carcinoma before transarterial chemoembolizationInoue, Akitoshi*; Uemura, Ryo; Takaki, Kai; Sonoda, Akinaga; Ota, Shinichi; Nitta, Norihisa; Batsaikhan, Bolorkhand; Takahashi, Hiroaki; Watanabe, YoshiyukiEUROPEAN JOURNAL OF RADIOLOGY, 2022, 154: 110420.
- Using 80 kVp on a 320-row scanner for hepatic multiphasic CT reduces the contrast dose by 50 % in patients at risk for contrast-induced nephropathyTaguchi, Narumi; Oda, Seitaro*; Utsunomiya, Daisuke; Funama, Yoshinori; Nakaura, Takeshi; Imuta, Masanori; Yamamura, Sadahiro; Yuki, Hideaki; Kidoh, Masafumi; Hirata, Kenichiro; Namimoto, Tomohiro; Hatemura, Masahiro; Kai, Noriyuki; Yamashita, YasuyukiEuropean Radiology, 2017, 27(2): 812-820.被引 23