ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Comparison of Multidetector Computed Tomography Angiography and Cholangiography Performed at 80 and 120 kVp in Live Liver Donors

Huber, Steffen*; Cornfeld, Daniel; Emre, Sukru H.; Israel, Gary M.
Journal of Computer Assisted Tomography2013-5DOI: 10.1097/RCT.0b013e318283bb5c
7被引3阅读
引用收藏
分享

摘要

Objective: The objective of this study was to compare the radiation exposure and image quality of contrast-enhanced multidetector computed tomography angiography (CTA) and computed tomography cholangiography (CTC) performed for living liver donor evaluation using 80 and 120 kVp. Methods: Ninety-three potential liver donors who underwent pre-operative contrast-enhanced 64 multidetector CTA and CTC were retrospectively divided into 2 groups: at 80 and at 120 kVp. An institutional review board waiver was obtained. Signal-to-noise ratio and contrast-tonoise ratio of the hepatic artery and common bile duct were obtained. The dose-length product was recorded. Image quality and visibility of hepatic artery and biliary tract anatomy were evaluated. Mann-Whitney U test was used for statistical evaluation. Results: Mean hepatic artery/common bile duct signal-to-noise ratio was 28.9/28.6 (SD, 14.2/10.0) at 80 kVp and 27.6/25.8 (SD, 8.0/6.2) at 120 kVp (P = 0.61/0.099). Mean hepatic artery/common bile duct contrast-to-noise ratio was 24.8/23.3 (SD, 12.9/8.6) at 80 kVp and 22.2/19.3 (SD, 7.7/5.0) at 120 kVp (P = 0.76/0.005). Mean CTA/CTC dose-length product was 279/281 (SD, 42/52) mGy-cm at 80 kVp and 407/451 (SD, 208/243) mGy-cm at 120 kVp (P = 0.026/0.002). Computed tomography cholangiography image quality and visibility of biliary tract anatomy were not significantly different at 80 versus 120 kVp (all P > 0.13). Computed tomography angiography image quality was significantly lower (P < 0.01), and the noise scores significantly higher (P < 0.01) at 80 versus 120 kVp, but diagnostic. Conclusions: Contrast-enhanced CTA and CTC performed at 80 kVp result in comparable image quality and anatomical evaluation with reduced radiation exposure when compared with 120 kVp.

学科与关键词

关键词
CT cholangiographyCTAimage qualitydose reductionliving liver donorlow tube voltage
相关
加载中…
  • CT Angiography in Potential Living Kidney Donors: 80 kVp Versus 120 kVp
    Davarpanah, Amir H.*; Pahade, Jay K.; Cornfeld, Dan; Ghita, Monica; Kulkarni, Sanjay; Israel, Gary M.American Journal of Roentgenology, 2013, 201(5): W753-W760.被引 12
  • Clinical impact of low tube voltage computed tomography during hepatic arteriography with low iodine to detect hepatocellular carcinoma before transarterial chemoembolization
    Inoue, Akitoshi*; Uemura, Ryo; Takaki, Kai; Sonoda, Akinaga; Ota, Shinichi; Nitta, Norihisa; Batsaikhan, Bolorkhand; Takahashi, Hiroaki; Watanabe, YoshiyukiEUROPEAN JOURNAL OF RADIOLOGY, 2022, 154: 110420.
  • Using 80 kVp on a 320-row scanner for hepatic multiphasic CT reduces the contrast dose by 50 % in patients at risk for contrast-induced nephropathy
    Taguchi, Narumi; Oda, Seitaro*; Utsunomiya, Daisuke; Funama, Yoshinori; Nakaura, Takeshi; Imuta, Masanori; Yamamura, Sadahiro; Yuki, Hideaki; Kidoh, Masafumi; Hirata, Kenichiro; Namimoto, Tomohiro; Hatemura, Masahiro; Kai, Noriyuki; Yamashita, YasuyukiEuropean Radiology, 2017, 27(2): 812-820.被引 23
查看全部 →

发表信息

论文状态
公开发表
期刊
Journal of Computer Assisted Tomography
发表日期
2013-05
卷期
第 37 卷, 第 3 期
页码
443-449
DOI
10.1097/RCT.0b013e318283bb5c
语言
ENGLISH
期刊等级
Q3
成果收录
SCIE

作者

  • H

    Huber, Steffen (通讯) (第一作者)

  • C

    Cornfeld, Daniel

查看全部 4 位作者收起作者
  • E

    Emre, Sukru H.

  • I

    Israel, Gary M.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417