ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

CT Evaluation of Small-Diameter Coronary Artery Stents: Effect of an Integrated Circuit Detector with Iterative Reconstruction

Geyer, Lucas L.; Glenn, G. Russell; De Cecco, Carlo Nicola; Van Horn, Mark; Canstein, Christian; Silverman, Justin R.; Krazinski, Aleksander W.; Kemper, Jenny M.; Bucher, Andreas; Ebersberger, Ullrich; Costello, Philip; Bamberg, Fabian; Schoepf, U. Joseph*
RADIOLOGY2015-9DOI: 10.1148/radiol.15140427
19被引1阅读
引用收藏
分享

摘要

Purpose: To use suitable objective methods of analysis to assess the influence of the combination of an integrated-circuit computed tomographic (CT) detector and iterative reconstruction (IR) algorithms on the visualization of small (<= 3-mm) coronary artery stents. Materials and Methods: By using a moving heart phantom, 18 data sets obtained from three coronary artery stents with small diameters were investigated. A second-generation dual-source CT system equipped with an integrated-circuit detector was used. Images were reconstructed with filtered back-projection (FBP) and IR at a section thickness of 0.75 mm (FBP75 and IR75, respectively) and IR at a section thickness of 0.50 mm (IR50). Multirow intensity profiles in Hounsfield units were modeled by using a sum-of-Gaussians fit to analyze in-plane image characteristics. Out-of-plane image characteristics were analyzed with z upslope of multicolumn intensity profiles in Hounsfield units. Statistical analysis was conducted with one-way analysis of variance and the Student t test. Results: Independent of stent diameter and heart rate, IR75 resulted in significantly increased xy sharpness, signal-to-noise ratio, and contrast-to-noise ratio, as well as decreased blurring and noise compared with FBP75 (eg, 2.25-mm stent, 0 beats per minute; xy sharpness, 278.2 vs 252.3; signal-to-noise ratio, 46.6 vs 33.5; contrast-to-noise ratio, 26.0 vs 16.8; blurring, 1.4 vs 1.5; noise, 15.4 vs 21.2; all P < .001). In the z direction, the upslopes were substantially higher in the IR50 reconstructions (2.25-mm stent: IR50, 94.0; IR75, 53.1; and FBP75, 48.1; P < .001). Conclusion: The implementation of an integrated-circuit CT detector provides substantially sharper out-of-plane resolution of coronary artery stents at 0.5-mm section thickness, while the use of iterative image reconstruction mostly improves in-plane stent visualization.

学科与关键词

关键词
IN-VITRO EVALUATIONCARDIAC COMPUTED-TOMOGRAPHYHIGH-RESOLUTION KERNELHEART-RATESDUAL-SOURCEIMAGE QUALITYPHANTOMANGIOGRAPHYVISUALIZATIONPERFORMANCE
相关
加载中…
  • Coronary CT Angiography with Use of Iterative Reconstruction Algorithm in Coronary Stenting: A Systematic Review of Image Quality, Diagnostic Value and Radiation Dose
    Al Shammakhi, Ahmed; Sun, Zhonghua*Journal of Medical Imaging and Health Informatics, 2015, 5(1): 103-109.被引 1
  • Comparison of the Effect of Iterative Reconstruction versus Filtered Back Projection on Cardiac CT Postprocessing
    Spears, J. Reid; Schoepf, U. Joseph*; Henzler, Thomas; Joshi, Gayatri; Moscariello, Antonio; Vliegenthart, Rozemarijn; Cho, Young Jun; Apfaltrer, Paul; Rowe, Garrett; Weininger, Markus; Ebersberger, UllrichACADEMIC RADIOLOGY, 2014, 21(3): 318-324.被引 15
  • In vivo coronary artery plaque assessment with computed tomography angiography: is there an impact of iterative reconstruction on plaque volume and attenuation metrics?
    Chen, Zhongyi; Boldeanu, Irina; Nepveu, Simon; Durand, Madeleine; Chin, Anne S.; Kauffmann, Claude; Mansour, Samer; Soulez, Gilles; Tremblay, Cecile; Chartrand-Lefebvre, Carl*Acta Radiologica, 2017, 58(6): 660-669.被引 12
查看全部 →

发表信息

论文状态
公开发表
期刊
RADIOLOGY
发表日期
2015-09
卷期
第 276 卷, 第 3 期
页码
706-714
DOI
10.1148/radiol.15140427
语言
ENGLISH
期刊收录
SCIE
期刊等级
Q1
成果收录
SCIE
资助标注
Bayer; Bracco; GE; Medrad; Siemens

作者

  • G

    Geyer, Lucas L. (第一作者)

  • G

    Glenn, G. Russell

查看全部 13 位作者收起作者
  • D

    De Cecco, Carlo Nicola

  • V

    Van Horn, Mark

  • C

    Canstein, Christian

  • S

    Silverman, Justin R.

  • K

    Krazinski, Aleksander W.

  • K

    Kemper, Jenny M.

  • B

    Bucher, Andreas

  • E

    Ebersberger, Ullrich

  • C

    Costello, Philip

  • B

    Bamberg, Fabian

  • S

    Schoepf, U. Joseph (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417