The influence of filtered back-projection and iterative reconstruction on partial volume correction in PET

Kops, ER*; Krause, BJ河北医科大学
Nuklearmedizin2005
6被引8阅读
引用收藏
分享

摘要

Aim: We assess the influence of the reconstruction algorithms [OS-EM for the iterative one vs. a filtered back-projection in Fourier space (DiFT)] on partial volume correction in PET employing a fully 3D 3-compartment MR based PV-correction algorithm. The gray matter voxels in the PET image - after removal of the white matter and cerebrospinal fluid contribution - are corrected voxel-by-voxel using the image resolution. Material, methods: Phantom measurements and one healthy human brain FDG study were carried out. For the OSEM reconstruction, a combination of iteration steps and subset numbers (It/Sub) was used, whereby in case of no-convergence the image resolution had to be fined. The results from the DiFT reconstruction were equivalent to those obtained from the OSEM reconstruction with 10/32 combination for objects with widespread activity concentration. For the sphere phantom, the mean recovery based on the actual values achieved 99.2% +/- 1.8 for all spheres and all reconstruction modes and It/sub combinations (except for 2/8). In case of the Hoffman 3D brain phantom the mean recovery of the cortical regions was 101% +/- 1.2 (the increase based on the uncorrected values: 35.5% +/- 1.5), while the subcortical regions reached a mean recovery of 80% with an increase of 43.9% +/- 2.5. For the human data, an increase of the metabolized values of several cortical regions ranged between 42% and 48% independent from the reconstruction mode. Conclusions: Our data show that the 3-compartment fully 3-D MR based PV-correction is sensitive to the choice of reconstruction algorithms and to the parameter choice. They indicate that despite improved spatial resolution, the use of the iterative reconstruction algorithm for PV-correction results in similar recovery factors when compared to a correction using DiFT reconstruction, insofar the image resolution values are fitted at the It/Sub combinations.

学科与关键词

关键词
PETMR imaging3-dimensional partial volume correctionreconstructionfiltered back-projectionOSEMphantom experiments
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
Nuklearmedizin
发表日期
2005
卷期
第 44 卷, 第 3 期
页码
99-106
语言
MULTI-LANGUAGE
成果收录
SCIE

作者

  • K

    Kops, ER (通讯) (第一作者)

    inst med

  • K

    Krause, BJ

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417