ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Registration of myocardial PET and SPECT for viability assessment using mutual information

Marinelli, Martina*; Martinez-Moeller, Axel; Jensen, Brian; Positano, Vincenzo; Weismueller, Susanne; Navab, Nassir; Landini, Luigi; Schwaiger, Markus; Nekolla, Stephan G.
Medical Physics2010-6DOI: 10.1118/1.3395554
11被引1阅读
引用收藏
分享

摘要

Purpose: The combination of sequentially acquired cardiac PET and SPECT data integrating metabolic and perfusion information allows the assessment of myocardial viability, a relevant clinical parameter for the management of patients who have suffered myocardial infarction and are now candidates for complex and cost intensive therapies such as bypass surgery. However, registration of cardiac functional datasets acquired on different imaging systems is limited by the difficulty to define anatomical landmarks and by the relatively poor inherent spatial resolution. In this article, the authors sought to evaluate whether it is possible to automatically register FDG-PET and sestamibi-SPECT cardiac data. Methods: Automatic rigid registration was implemented with the ITK framework using Mattes mutual information as the similarity measure and a quaternion to represent the rotational component. The goodness of the alignment was evaluated by computing the mean target registration error (mTRE) at the myocardial wall. The registration parameters were optimized for robustness and speed using the data from 11 cardiac patients undergoing both PET and SPECT examinations (training datasets). The optimized algorithm was applied on the PET and SPECT data from 11 further patients (evaluation datasets). Quantitative (mTRE calculation) and visual (scoring method) comparisons were performed between automatic and manual registrations. Moreover, the automatic registration was also compared to the registration implicitly defined in the standard clinical analysis. Results: The registration parameters were successfully optimized and resulted in a mean mTRE of 1.13 mm and 1.2 s average runtime on standard computer hardware for the training datasets. Automatic registration in the 11 validation datasets resulted in an average mTRE of 2.3 mm, with 7.5 mm mTRE in the worst case and an average runtime of 1.6 s. Automatic registration outperformed manual registrations both for the mTRE and for the visual assessment. Automatic registration also resulted in higher accuracy and better visual assessment as compared to the registration implicitly performed in the standard clinical analysis. Conclusions: The results demonstrate the possibility to successfully perform mutual information based registration of PET and SPECT cardiac data, allowing an improved workflow for the sequentially acquired cardiac datasets, in general, and specifically for the assessment of myocardial viability.

学科与关键词

关键词
registrationmutual informationfunctional imagesmyocardial viability
相关
加载中…
  • Correlation of SPECT and PET cardiac images by a surface matching registration technique
    Gilardi, MC; Rizzo, G; Savi, A; Landoni, C; Bettinardi, V; Rossetti, C; Striano, G; Fazio, FCOMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1998, 22(5): 391-398.被引 22
  • Automatic detection of left and right ventricles from CTA enables efficient alignment of anatomy with myocardial perfusion data
    Piccinelli, Marina*; Faber, Tracy L.; Arepalli, Chesnal D.; Appia, Vikram; Vinten-Johansen, Jakob; Schmarkey, Susan L.; Folks, Russell D.; Garcia, Ernest V.; Yezzi, AnthonyJournal of Nuclear Cardiology, 2014, 21(1): 96-108.被引 4
  • Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT
    Nakazato, Ryo; Dey, Damini; Alexanderson, Erick; Meave, Aloha; Jimenez, Moises; Romero, Edgar; Jacome, Rodrigo; Pena, Marco; Berman, Daniel S.; Slomka, Piotr J.*Journal of Nuclear Cardiology, 2012, 19(3): 482-491.被引 16
查看全部 →

发表信息

论文状态
公开发表
期刊
Medical Physics
发表日期
2010-06
卷期
第 37 卷, 第 6 期
页码
2414-2424
DOI
10.1118/1.3395554
语言
ENGLISH
成果收录
SCIE
资助标注
Siemens Healthcare, Erlangen, Germany

作者

  • M

    Marinelli, Martina (通讯) (第一作者)

  • M

    Martinez-Moeller, Axel

查看全部 9 位作者收起作者
  • J

    Jensen, Brian

  • P

    Positano, Vincenzo

  • W

    Weismueller, Susanne

  • N

    Navab, Nassir

  • L

    Landini, Luigi

  • S

    Schwaiger, Markus

  • N

    Nekolla, Stephan G.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417