ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Automatic 3D registration of dynamic stress and rest 82Rb and flurpiridaz F 18 myocardial perfusion PET data for patient motion detection and correction

Woo, Jonghye; Tamarappoo, Balaji; Dey, Damini; Nakazato, Ryo; Le Meunier, Ludovic; Ramesh, Amit; Lazewatsky, Joel; Germano, Guido; Berman, Daniel S.; Slomka, Piotr J.*
Medical Physics2011-11DOI: 10.1118/1.3656951
34被引1阅读
引用收藏
分享

摘要

Purpose: The authors aimed to develop an image-based registration scheme to detect and correct patient motion in stress and rest cardiac positron emission tomography (PET)/CT images. The patient motion correction was of primary interest and the effects of patient motion with the use of flurpiridaz F 18 and Rb-82 were demonstrated. Methods: The authors evaluated stress/rest PET myocardial perfusion imaging datasets in 30 patients (60 datasets in total, 21 male and 9 female) using a new perfusion agent (flurpiridaz F 18) (n = 16) and Rb-82 (n = 14), acquired on a Siemens Biograph-64 scanner in list mode. Stress and rest images were reconstructed into 4 (Rb-82) or 10 (flurpiridaz F 18) dynamic frames (60 s each) using standard reconstruction (2D attenuation weighted ordered subsets expectation maximization). Patient motion correction was achieved by an image-based registration scheme optimizing a cost function using modified normalized cross-correlation that combined global and local features. For comparison, visual scoring of motion was performed on the scale of 0 to 2 (no motion, moderate motion, and large motion) by two experienced observers. Results: The proposed registration technique had a 93% success rate in removing left ventricular motion, as visually assessed. The maximum detected motion extent for stress and rest were 5.2 mm and 4.9 mm for flurpiridaz F 18 perfusion and 3.0 mm and 4.3 mm for Rb-82 perfusion studies, respectively. Motion extent (maximum frame-to-frame displacement) obtained for stress and rest were (2.2 +/- 1.1, 1.4 +/- 0.7, 1.9 +/- 1.3) mm and (2.0 +/- 1.1, 1.2 +/- 0.9, 1.9 +/- 0.9) mm for flurpiridaz F 18 perfusion studies and (1.9 +/- 0.7, 0.7 +/- 0.6, 1.3 +/- 0.6) mm and (2.0 +/- 0.9, 0.6 +/- 0.4, 1.2 +/- 1.2) mm for Rb-82 perfusion studies, respectively. A visually detectable patient motion threshold was established to be >= 2.2 mm, corresponding to visual user scores of 1 and 2. After motion correction, the average increases in contrast-to-noise ratio (CNR) from all frames for larger than the motion threshold were 16.2% in stress flurpiridaz F 18 and 12.2% in rest flurpiridaz F 18 studies. The average increases in CNR were 4.6% in stress Rb-82 studies and 4.3% in rest Rb-82 studies. Conclusions: Fully automatic motion correction of dynamic PET frames can be performed accurately, potentially allowing improved image quantification of cardiac PET data.

学科与关键词

关键词
motion correction and detectionimage registrationflurpiridaz F 18cardiac PET myocardial perfusion imaging
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
Medical Physics
发表日期
2011-11
卷期
第 38 卷, 第 11 期
页码
6313-6326
DOI
10.1118/1.3656951
语言
ENGLISH
成果收录
SCIE
资助标注
National Heart, Lung, and Blood Institute/National Institutes of Health (NHLBI/NIH) [R01HL089765-01]

作者

  • W

    Woo, Jonghye (第一作者)

  • T

    Tamarappoo, Balaji

查看全部 10 位作者收起作者
  • D

    Dey, Damini

  • N

    Nakazato, Ryo

  • L

    Le Meunier, Ludovic

  • R

    Ramesh, Amit

  • L

    Lazewatsky, Joel

  • G

    Germano, Guido

  • B

    Berman, Daniel S.

  • S

    Slomka, Piotr J. (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417