ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Individually tailored contrast enhancement in CT pulmonary angiography

Hendriks, Babs M. F.; Kok, Madeleine; Mihl, Casper; Bekkers, Sebastiaan C. A. M.; Wildberger, Joachim E.; Das, Marco*
British Journal of Radiology2016DOI: 10.1259/bjr.20150850
32被引1阅读
引用收藏
分享

摘要

Objective: The purpose was to evaluate individually shaped contrast media (CM) delivery in CT pulmonary angiography (CTPA) for suspected pulmonary embolism (PE). Methods: 100 consecutive emergency patients with clinical suspicion of PE were evaluated. High-pitch CTPA was performed on a second-generation dual-source CT using the following parameters: 100kV, 200-250mAsref, rotation time 0.28s, 128 x 0.6mm col. and image reconstruction 1.0/0.8mm (B30f). Group 1 (n = 50) then received a fixed CM bolus (3005mgl ml(-1), volume = 90ml and flow rate = 6ml s(-1)); Group 2 (n = 50) received a body weight-adapted CM bolus determined by dedicated contrast injection software. For analysis, groups were further subdivided into low-weight (40-75 kg) and high-weight (76-117 kg) groups. Technical image quality was graded using a four-point Likert scale (15non-diagnostic; 2 = diagnostic; 3 = good and 4 = excellent image quality) at the level of the pulmonary trunk and pulmonary arteries. Objective image quality analysis was performed by measuring contrast enhancement in Hounsfield units (HU) at the same levels. Attenuation levels > 180HU were considered diagnostic. Results: All examinations were graded as diagnostic at each level. The individual minimum pulmonary attenuation was 184 and 270HU for Group 1 and 2, respectively. Mean attenuation was as follows: Group 1: 475 +/- 105HU (40-75 kg) and 402 +/- 115HU (76-117 kg), p < 0.03. Group 2: 424 +/- 76HU (40-75 kg) and 418 +/- 100HU (76-117 kg), p = 0.8. For Group 2, CM volumes were: 55 +/- 5ml (40-75 kg) and 66 +/- 5ml (76-117 kg), leading to 16-51% CM reduction. Conclusion: Even under emergency conditions, individualized CM protocols can provide diagnostic and robust image quality in CTPA for PE with a substantial reduction of CM volume for lower weight patients, compared with a fixed CM protocol. Advances in knowledge: CM volume can substantially be reduced by using individualized CM protocols in CT angiography for PE without compromising the diagnostic image quality.

学科与关键词

关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHYLOW-TUBE VOLTAGEIODINE DELIVERY RATEDUAL-ENERGY CTIMAGE QUALITYPATIENT WEIGHTABDOMINAL CTITERATIVE RECONSTRUCTIONINDUCED NEPHROPATHYFLOW-RATES
相关
加载中…
  • Use of pulmonary CT angiography with low tube voltage and low-iodine-concentration contrast agent to diagnose pulmonary embolism
    Hu, Xuemei; Ma, Liya; Zhang, Jinhua; Li, Zhen; Shen, Yaqi*; Hu, DaoyuScientific Reports, 2017, 7: 12741.被引 9
  • CT pulmonary angiography: simultaneous low-pitch dualsource acquisition mode with 70kVp and 40ml of contrast medium and comparison with high-pitch spiral dual-source acquisition with automated tube potential selection
    Boos, Johannes*; Kroepil, Patric; Lanzman, Rotem S.; Aissa, Joel; Schleich, Christoph; Heusch, Philipp; Sawicki, Lino M.; Antoch, Gerald; Thomas, ChristophBritish Journal of Radiology, 2016, 89(1062): 20151059.被引 25
  • Ultra-low dose contrast CT pulmonary angiography in oncology patients using a high-pitch helical dual-source technology
    Rajiah, Prabhakar*; Ciancibello, Leslie; Novak, Ronald; Sposato, Jennifer; Landeras, Luis; Gilkeson, RobertDiagnostic and Interventional Radiology, 2019, 25(3): 195-203.被引 17
查看全部 →

发表信息

论文状态
公开发表
期刊
British Journal of Radiology
发表日期
2016
卷期
第 89 卷, 第 1061 期
页码
20150850
DOI
10.1259/bjr.20150850
语言
ENGLISH
成果收录
SCIE

作者

  • H

    Hendriks, Babs M. F. (第一作者)

  • K

    Kok, Madeleine

查看全部 6 位作者收起作者
  • M

    Mihl, Casper

  • B

    Bekkers, Sebastiaan C. A. M.

  • W

    Wildberger, Joachim E.

  • D

    Das, Marco (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417