ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Clinical validation of S-Detect? mode in semi-automated ultrasound classification of thyroid lesions in surgical office

Barczynski, Marcin*; Stopa-Barczynska, Malgorzata; Wojtczak, Beata; Czarniecka, Agnieszka; Konturek, Aleksander
Gland Surgery2020-2DOI: 10.21037/gs.2019.12.23
23被引2阅读
引用收藏
分享

摘要

Background: In recent years well-recognized scientific societies introduced guidelines for ultrasound (US) malignancy risk stratification of thyroid nodules. These guidelines categorize the risk of malignancy in relation to a combination of several US features. Based on these US image lexicons an US-based computer-aided diagnosis (CAD) systems were developed. Nevertheless, their clinical utility has not been evaluated in any study of surgeon-performed office US of the thyroid. Hence, the aim of this pilot study was to validate s-Detect (TM) mode in semi-automated US classification of thyroid lesions during surgeon-performed office US. Methods: This is a prospective study of 50 patients who underwent surgeon-performed thyroid US (basic US skills without CAD vs. with CAD vs. expert US skills without CAD) in the out-patient office as part of the preoperative workup. The real-time CAD system software using artificial intelligence (s-Detect (TM) for Thyroid; Samsung Medison Co.) was integrated into the RS85 US system. Primary outcome was CAD system added-value to the surgeon-performed office US evaluation. Secondary outcomes were: diagnostic accuracy of CAD system, intra and interobserver variability in the US assessment of thyroid nodules. Surgical pathology report was used to validate the pre-surgical diagnosis. Results: CAD system added-value to thyroid assessment by a surgeon with basic US skills was equal to 6% (overall accuracy of 82% for evaluation with CAD vs. 76% for evaluation without CAD system; P<0.001), and final diagnosis was different than predicted by US assessment in 3 patients (1 more true-positive and 2 more true-negative results). How ever, CAD system was inferior to thyroid assessment by a surgeon with expert US skills in 6 patients who had false-positive results (P<0.001). Conclusions: The sensitivity and negative predictive value of CAD system for US classification of thyroid lesions were similar as surgeon with expert US skills whereas specificity and positive predictive value were significantly inferior but markedly better than judgement of a surgeon with basic US skills alone.

学科与关键词

关键词
Thyroid lesionsthyroid cancerthyroid ultrasoundcomputer-aided diagnosis (CAD)artificial intelligence
相关
加载中…
  • REAL-WORLD PERFORMANCE OF COMPUTER-AIDED DIAGNOSIS SYSTEM FOR THYROID NODULES USING ULTRASONOGRAPHY
    Kim, Hye Lin; Ha, Eun Ju*; Han, MiranUltrasound in Medicine and Biology, 2019, 45(10): 2672-2678.被引 42
  • Applications of machine learning and deep learning to thyroid imaging: where do we stand?
    Ha, Eun Ju; Baek, Jung Hwan*Ultrasonography, 2021, 40(1): 23-29.被引 23
  • The value of S-Detect in improving the diagnostic performance of radiologists for the differential diagnosis of thyroid nodules
    Wei, Qi; Zeng, Shu-E; Wang, Li-Ping; Yan, Yu-Jing; Wang, Ting; Xu, Jian-Wei; Zhang, Meng-Yi; Lv, Wen-Zhi; Cui, Xin-Wu*; Dietrich, Christoph F.Medical Ultrasonography, 2020, 22(4): 415-423.被引 22
查看全部 →

发表信息

论文状态
公开发表
期刊
Gland Surgery
发表日期
2020-02
卷期
第 9 卷
页码
S77-S85
DOI
10.21037/gs.2019.12.23
期刊收录
NSL.SCIE
期刊等级
2区
成果收录
SCIE

作者

  • B

    Barczynski, Marcin (通讯) (第一作者)

  • S

    Stopa-Barczynska, Malgorzata

查看全部 5 位作者收起作者
  • W

    Wojtczak, Beata

  • C

    Czarniecka, Agnieszka

  • K

    Konturek, Aleksander

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417