摘要
To optimize and evaluate an ultra-low-dose (ULD) technique for CT coronary angiography (CTCA). Eighty-two patients were randomly divided into two groups. ULD and routine CTCA were performed in groups A and B. Image quality, radiation dose and contrast agent were evaluated. The effective dose (ED) was 0.20 +/- 0.01 mSv for the ULD technique, a decrease of 87% (t = - 21.182, P < 0.001) compared with the control group. The total iodine content was 8.10 +/- 0 g, a decrease of 62% (t = - 73.458, P < 0.001) compared with 21.10 +/- 1.15 g for the control group. The assessment rates for both groups were the same (99.26 vs 99.64%, chi (2) = 0.727, P = 0.394). The contrast-to-noise ratio was 19.31 +/- 7.95 for group A and 20.73 +/- 5.07 for group B: the difference was not statistically significant (t = - 1.678, P = 0.095). Using an ultra-low radiation dose and contrast agent technique, while maintaining an assessable image and improving the safety of the medical examination, was a feasible and reliable method for CTCA.
学科与关键词
- Low-Concentration Contrast Medium for 128-Slice Dual-Source CT Coronary Angiography at a Very Low Radiation Dose Using Prospectively ECG-Triggered High-Pitch Spiral AcquisitionZheng, Minwen*; Wu, Yongjie; Wei, Mengqi; Liu, Ying; Zhao, Hongliang; Li, JianACADEMIC RADIOLOGY, 2015, 22(2): 195-202.被引 23
- Low kV and Low Concentration Contrast Agent with Iterative Reconstruction of Computed Tomography (CT) Coronary Angiography: A Preliminary StudyZhang, Hong*; Ma, Yanhe; Lyu, Jun; Yang, Yapeng; Yuan, Wei; Song, ZhenchunMEDICAL SCIENCE MONITOR, 2017, 23: 5005-5010.被引 7
- Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation doseLeschka, Sebastian; Stolzmann, Paul; Schmid, Florian T.; Scheffel, Hans; Stinn, Bjoern; Marincek, Borut; Alkadhi, Hatem*; Wildermuth, SimonEuropean Radiology, 2008, 18(9): 1809-1817.被引 231