ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Optimization of a chest computed tomography protocol for detecting pure ground glass opacity nodules: A feasibility study with a computer-assisted detection system and a lung cancer screening phantom

Kang, Seongmin; Kim, Tae Hoon; Shin, Jae Min; Han, Kyunghwa; Kim, Ji Young; Min, Baeggi; Park, Chul Hwan*
PLoS One2020-5-22DOI: 10.1371/journal.pone.0232688
4被引1阅读
引用收藏
分享

摘要

Objective This study aimed to optimize computed tomography (CT) parameters for detecting ground glass opacity nodules (GGNs) using a computer-assisted detection (CAD) system and a lung cancer screening phantom. Methods A lung cancer screening phantom containing 15 artificial GGNs (-630 Hounsfield unit [HU], 2-10 mm) in the left lung was examined with a CT scanner. Three tube voltages of 80, 100, and 120 kVp were used in combination with five tube currents of 25, 50, 100, 200, and 400 mA; additionally, three slice thicknesses of 0.625, 1.25, and 2.5 mm and four reconstruction algorithms of adaptive statistical iterative reconstruction (ASIR-V) of 30, 60, and 90% were used. For each protocol, accuracy of the CAD system was evaluated for nine target GGNs of 6, 8, or 10 mm in size. The cut-off size was set to 5 mm to minimize false positives. Results Among the 180 combinations of tube voltage, tube current, slice thickness, and reconstruction algorithms, combination of 80 kVp, 200 mA, and 1.25-mm slice thickness with an ASIR-V of 90% had the best performance in the detection of GGNs with six true positives and no false positives. Other combinations had fewer than five true positives. In particular, any combinations with a 0.625-mm slice thickness had 0 true positive and at least one false positive result. Conclusion Low-voltage chest CT with a thin slice thickness and a high iterative reconstruction algorithm improve the detection rate of GGNs with a CAD system in a phantom model, and may have potential in lung cancer screening.

学科与关键词

关键词
RADIATION-DOSE REDUCTIONLOW-TUBE-VOLTAGETHIN-SECTION CTITERATIVE RECONSTRUCTIONIMAGE QUALITYAIDED DIAGNOSISABDOMINAL CTCADALGORITHMCONTRAST
相关
加载中…
  • Diagnostic validation of a deep learning nodule detection algorithm in low-dose chest CT: determination of optimized dose thresholds in a virtual screening scenario
    Peters, Alan A.*; Huber, Adrian T.; Obmann, Verena C.; Heverhagen, Johannes T.; Christe, Andreas; Ebner, LukasEuropean Radiology, 2022, 32(6): 4324-4332.被引 8
  • Application of computer-aided detection (CAD) software to automatically detect nodules under SDCT and LDCT scans with different parameters
    Hu, Qiongjie; Chen, Chong; Kang, Shichao; Sun, Ziyan; Wang, Yujin; Xiang, Min; Guan, Hanxiong; Xia, Liming*; Wang, Shaofang*Computers in Biology and Medicine, 2022, 146: 105538.
  • Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient Size
    Deak, Zsuzsanna; Maertz, Friedrich; Meurer, Felix; Notohamiprodjo, Susan; Mueck, Fabian; Geyer, Lucas L.; Reiser, Maximilian F.; Wirth, StefanJournal of Computer Assisted Tomography, 2017, 41(2): 254-262.被引 3
查看全部 →

发表信息

论文状态
公开发表
期刊
PLoS One
发表日期
2020-05-22
卷期
第 15 卷, 第 5 期
页码
e0232688
DOI
10.1371/journal.pone.0232688
语言
ENGLISH
期刊收录
NSL.SCIE
期刊等级
3区
成果收录
SCIE
资助标注
Yonsei University College of Medicine [2017-320040]

作者

  • K

    Kang, Seongmin (第一作者)

  • K

    Kim, Tae Hoon

查看全部 7 位作者收起作者
  • S

    Shin, Jae Min

  • H

    Han, Kyunghwa

  • K

    Kim, Ji Young

  • M

    Min, Baeggi

  • P

    Park, Chul Hwan (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417