ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Convolution neural network toward Monte Carlo photon dose calculation in radiation therapy

Zhang, Bailin; Liu, Xiaowei; Chen, Lixin; Zhu, Jinhan*广州中医药大学; 中山大学
Medical Physics2022-2DOI: 10.1002/mp.15408
7被引14阅读
引用收藏
分享

摘要

Purpose The Monte Carlo (MC) algorithm has been widely accepted as the most accurate algorithm for dosimetric calculations under various conditions in radiotherapy. However, the calculation time remains an important obstacle hindering the routine use of MC in clinical settings. In this study, full MC three-dimensional dose distributions were obtained with the inputs of the total energy release per unit mass (TERMA) distributions and the electron density (ED) distributions using a convolutional neural network (CNN). A new Dose-mixup data augmentation routine and training strategy are proposed and applied in the training process. Attempts were made to reduce the calculation time while ensuring that the calculation accuracy is comparable to that of the MC. Methods Datasets were generated via the MC with random rectangular field sizes, random iso-centers, and random gantry angles for head and neck computed tomography (CT) images with Mohan 6-MV spectrum photon beams. 1500 samples were generated for the training set, and 150 samples were generated for the validation set. The T-MC Net model was obtained with the Dose-mixup data augmentation routine. The new CTs were used to test the performance of the model in the rectangular fields and the intensity-modulated radiation therapy (IMRT) fields. The mean +/- 95% confidence interval of gamma pass rates were calculated. Results For 150 rectangular field test samples, the 1%/2 mm, 2%/2 mm, and 3%/2 mm criteria gamma pass rates were 90.11% +/- 0.65%, 97.65% +/- 0.31%, and 99.16% +/- 0.19%, respectively. For the 100 IMRT field test samples, the 1%/2 mm, 2%/2 mm, and 3%/2 mm criteria gamma pass rates were 96.48% +/- 0.28%, 99.14% +/- 0.10%, and 99.63% +/- 0.06%, respectively. For the 7-fields IMRT plan, the 1%/2 mm, 2%/2 mm, and 3%/2 mm criteria gamma pass rates were 97.06%, 99.10%, and 99.52%, respectively. For the 9-fields IMRT plan, the 1%/2 mm, 2%/2 mm, and 3%/2 mm criteria gamma pass rates were 98.16%, 99.61%, and 99.89%, respectively. Conclusions The feasibility of calculating dose distribution using a CNN with the TERMA three-dimensional distribution and ED distribution was established. The dosimetric results were comparable to those of the full MC. The accuracy and speed of the proposed approach make it a potential solution for full MC in radiotherapy. This method may be used as an acceleration engine for the dose algorithm and shows great potential for cases where fast dose calculations are needed.

学科与关键词

关键词
convolutional neural networkdose calculationMonte Carlo algorithmradiotherapy
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
Medical Physics
发表日期
2022-02
卷期
第 49 卷, 第 2 期
页码
1248-1261
DOI
10.1002/mp.15408
语言
ENGLISH
期刊等级
3区
成果收录
SCIE
资助标注
National Natural Science Foundation of China [12005315]; Guangzhou Science and Technology Plan [202102010264]

作者

  • Z

    Zhang, Bailin (第一作者)

    2 · guangzhou univ chinese med

  • L

    Liu, Xiaowei

    sun yat sen univ

查看全部 4 位作者收起作者
  • C

    Chen, Lixin

    sun yat sen univ

  • Z

    Zhu, Jinhan (通讯)

    sun yat sen univ

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417