ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Prospective Study of Low- and Standard-dose Chest CT for Pulmonary Nodule Detection: A Comparison of Image Quality, Size Measurements and Radiation Exposure

Hu, Qiong-jie; Liu, Yi-wen; Chen, Chong; Kang, Shi-chao; Sun, Zi-yan; Wang, Yu-jin; Xiang, Min; Xia, Li-ming; Guan, Han-xiong*华中科技大学; 南方医科大学
Current Medical Science2021-10DOI: 10.1007/s11596-021-2433-z
3被引10阅读
引用收藏
分享

摘要

Objective To comprehensively and accurately analyze the out-performance of low-dose chest CT (LDCT) vs. standard-dose CT (SDCT). Methods The image quality, size measurements and radiation exposure for LDCT and SDCT protocols were evaluated. A total of 117 patients with extra-thoracic malignancies were prospectively enrolled for non-enhanced CT scanning using LDCT and SDCT protocols. Three experienced radiologists evaluated subjective image quality independently using a 5-point score system. Nodule detection efficiency was compared between LDCT and SDCT based on nodule characteristics (size and volume). Radiation metrics and organ doses were analyzed using Radimetrics. Results The images acquired with the LDCT protocol yielded comparable quality to those acquired with the SDCT protocol. The sensitivity of LDCT for the detection of pulmonary nodules (n=650) was lower than that of SDCT (n=660). There was no significant difference in the diameter and volume of pulmonary nodules between LDCT and SDCT (for BMI <22 kg/m(2), 4.37 vs. 4.46 mm, and 43.66 vs. 46.36 mm(3); for BMI >= 22 kg/m(2), 4.3 vs. 4.41 mm, and 41.66 vs. 44.86 mm(3)) (P>0.05). The individualized volume CT dose index (CTDIvol), the size specific dose estimate and effective dose were significantly reduced in the LDCT group compared with the SDCT group (all P<0.0001). This was especially true for dose-sensitive organs such as the lung (for BMI <22 kg/m(2), 2.62 vs. 12.54 mSV, and for BMI >= 22 kg/m(2), 1.62 vs. 9.79 mSV) and the breast (for BMI <22 kg/m(2), 2.52 vs. 10.93 mSV, and for BMI >= 22 kg/m(2), 1.53 vs. 9.01 mSV) (P<0.0001). Conclusion These results suggest that with the increases in image noise, LDCT and SDCT exhibited a comparable image quality and sensitivity. The LDCT protocol for chest scans may reduce radiation exposure by about 80% compared to the SDCT protocol.

学科与关键词

关键词
pulmonary nodulestomographyX-ray computedradiation dosagelungbreast
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
Current Medical Science
发表日期
2021-10
卷期
第 41 卷, 第 5 期
页码
966-973
DOI
10.1007/s11596-021-2433-z
期刊收录
NSL.CAST-E
期刊等级
4区
成果收录
SCIE

作者

  • H

    Hu, Qiong-jie (第一作者)

    huazhong univ sci & technol

  • L

    Liu, Yi-wen

    huazhong univ sci & technol

查看全部 9 位作者收起作者
  • C

    Chen, Chong

    huazhong univ sci & technol

  • K

    Kang, Shi-chao

    shenzhen matern & child healthcare hosp · southern med univ

  • S

    Sun, Zi-yan

    huazhong univ sci & technol

  • W

    Wang, Yu-jin

    huazhong univ sci & technol

  • X

    Xiang, Min

    huazhong univ sci & technol

  • X

    Xia, Li-ming

    huazhong univ sci & technol

  • G

    Guan, Han-xiong (通讯)

    huazhong univ sci & technol

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417