ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Retinal Specialist versus Artificial Intelligence Detection of Retinal Fluid from OCT Age-Related Eye Disease Study 2: 10-Year Follow-On Study

Keenan, Tiarnan D. L.*; Clemons, Traci E.; Domalpally, Amitha; Elman, Michael J.; Havilio, Moshe; Agron, Elvira; Benyamini, Gidi; Chew, Emily Y.
Ophthalmology2021-1DOI: 10.1016/j.opatha.2020.06.038
51被引5阅读
引用收藏
分享

摘要

Purpose: To evaluate the performance of retinal specialists in detecting retinal fluid presence in spectral domain OCT (SD-OCT) scans from eyes with age-related macular degeneration (AMD) and compare performance with an artificial intelligence algorithm. Design: Prospective comparison of retinal fluid grades from human retinal specialists and the Notal OCT Analyzer (NOA) on SD-OCT scans from 2 common devices. Participants: A total of 1127 eyes of 651 Age-Related Eye Disease Study 2 10-year Follow-On Study (AREDS2-10Y) participants with SD-OCT scans graded by reading center graders (as the ground truth). Methods: The AREDS2-10Y investigators graded each SD-OCT scan for the presence/absence of intraretinal and subretinal fluid. Separately, the same scans were graded by the NOA. Main Outcome Measures: Accuracy (primary), sensitivity, specificity, precision, and F1-score. Results: Of the 1127 eyes, retinal fluid was present in 32.8%. For detecting retinal fluid, the investigators had an accuracy of 0.805 (95% confidence interval [CI], 0.780-0.828), a sensitivity of 0.468 (95% CI, 0.416-0.520), a specificity of 0.970 (95% CI, 0.955-0.981). The NOA metrics were 0.851 (95% CI, 0.829-0.871), 0.822 (95% CI, 0.779-0.859), 0.865 (95% CI, 0.839-0.889), respectively. For detecting intraretinal fluid, the investigator metrics were 0.815 (95% CI, 0.792-0.837), 0.403 (95% CI, 0.349-0.459), and 0.978 (95% CI, 0.966-0.987); the NOA metrics were 0.877 (95% CI, 0.857-0.896), 0.763 (95% CI, 0.713-0.808), and 0.922 (95% CI, 0.902-0.940), respectively. For detecting subretinal fluid, the investigator metrics were 0.946 (95% CI, 0.931-0.958), 0.583 (95% CI, 0.471-0.690), and 0.973 (95% CI, 0.962-0.982); the NOA metrics were 0.863 (95% CI, 0.842-0.882), 0.940 (95% CI, 0.867-0.980), and 0.857 (95% CI, 0.835-0.877), respectively. Conclusions: In this large and challenging sample of SD-OCT scans obtained with 2 common devices, retinal specialists had imperfect accuracy and low sensitivity in detecting retinal fluid. This was particularly true for intraretinal fluid and difficult cases (with lower fluid volumes appearing on fewer B-scans). Artificial intelligence based detection achieved a higher level of accuracy. This software tool could assist physicians in detecting retinal fluid, which is important for diagnostic, re-treatment, and prognostic tasks. Published by Elsevier on behalf of the American Academy of Ophthalmology

学科与关键词

关键词
OPTICAL COHERENCE TOMOGRAPHYMACULAR DEGENERATIONIMAGING BIOMARKERSVISUAL-ACUITYRANIBIZUMABSEGMENTATIONQUANTIFICATIONPREVALENCEIDENTIFICATIONMORPHOLOGY
相关
加载中…
  • Automated Identification of Lesion Activity in Neovascular Age-Related Macular Degeneration
    Chakravarthy, Usha*; Goldenberg, Dafna; Young, Graham; Havilio, Moshe; Rafaeli, Omer; Benyamini, Gidi; Loewenstein, AnatOphthalmology, 2016, 123(8): 1731-1736.被引 81
  • Accuracy and feasibility with AI-assisted OCT in retinal disorder community screening
    Bai, Jianhao; Wan, Zhongqi; Li, Ping; Chen, Lei; Wang, Jingcheng; Fan, Yu; Chen, Xinjian*; Peng, Qing*; Gao, Peng*Frontiers in Cell and Developmental Biology, 2022, 10: 1053483.被引 9
  • Automated Quantitative Assessment of Retinal Fluid Volumes as Important Biomarkers in Degeneration
    Keenan, Tiarnan D. L.*; Chakravarthy, Usha; Loewenstein, Anat; Chew, Emily Y.; Schmidt-Erfurth, UrsulaAmerican Journal of Ophthalmology, 2021, 224: 267-281.被引 44
查看全部 →

发表信息

论文状态
公开发表
期刊
Ophthalmology
发表日期
2021-01
卷期
第 128 卷, 第 1 期
页码
100-109
DOI
10.1016/j.opatha.2020.06.038
语言
ENGLISH
期刊收录
NSL
期刊等级
1区
成果收录
SCIE
资助标注
Notal Vision Ltd.; National Eye Institute, National Institutes of Health, Department of Health and Human Services, Bethesda, Maryland [HHSN263201300005C]; EMMES Company, LLC; National Eye Institute [ZIAEY000489] Funding Source: NIH RePORTER

作者

  • K

    Keenan, Tiarnan D. L. (通讯) (第一作者)

  • C

    Clemons, Traci E.

查看全部 8 位作者收起作者
  • D

    Domalpally, Amitha

  • E

    Elman, Michael J.

  • H

    Havilio, Moshe

  • A

    Agron, Elvira

  • B

    Benyamini, Gidi

  • C

    Chew, Emily Y.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417