ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Hippocampal volume change measurement: Quantitative assessment of the reproducibility of expert manual outlining and the automated methods FreeSurfer and FIRST

Mulder, Emma R.; de Jong, Remko A.; Knol, Dirk L.; van Schijndel, Ronald A.; Cover, Keith S.; Visser, Pieter J.; Barkhof, Frederik; Vrenken, Hugo*
NeuroImage2014-5-15DOI: 10.1016/j.neuroimage.2014.01.058
101被引1阅读
引用收藏
分享

摘要

Background: To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but this has not been investigated. Aim: To determine the reproducibilities of expert manual outlining and two common automated methods for measuring hippocampal atrophy rates in healthy aging, MCI and AD. Methods: From the Alzheimer's Disease Neuroimaging Initiative (ADNI), 80 subjects were selected:20 patients with AD, 40 patients with mild cognitive impairment (MCI) and 20 healthy controls (HCs). Left and right hippocampal volume change between baseline and month-12 visit was assessed by using expert manual delineation, and by the automated software packages FreeSurfer (longitudinal processing stream) and FIRST. To assess reproducibility of the measured hippocampal volume change, both back-to-back (BTB) MPRAGE scans available for each visit were analyzed. Hippocampal volume change was expressed in mu L, and as a percentage of baseline volume. Reproducibility of the 1-year hippocampal volume change was estimated from the BTB measurements by using linear mixed model to calculate the limits of agreement (LoA) of each method, reflecting its measurement uncertainty. Using the delta method, approximate p-values were calculated for the pairwise comparisons between methods. Statistical analyses were performed both with inclusion and exclusion of visibly incorrect segmentations. Results: Visibly incorrect automated segmentation in either one or both scans of a longitudinal scan pair occurred in 7.5% of the hippocampi for FreeSurfer and in 6.9% of the hippocampi for FIRST. After excluding these failed cases, reproducibility analysis for 1-year percentage volume change yielded LoA of +/- 7.2% for FreeSurfer, +/- 9.7% for expert manual delineation, and +/- 10.0% for FIRST. Methods ranked the same for reproducibility of 1-year mu 1. volume change, with LoA of +/- 218 mu L for FreeSurfer, +/- 319 mu L for expert manual delineation, and 333 mu L for FIRST. Approximate p-values indicated that reproducibility was better for FreeSurfer than for manual or FIRST, and that manual and FIRST did not differ. Inclusion of failed automated segmentations led to worsening of reproducibility of both automated methods for 1-year raw and percentage volume change. Conclusion: Quantitative reproducibility values of 1-year microliter and percentage hippocampal volume change were roughly similar between expert manual outlining, FIRST and FreeSurfer, but FreeSurfer reproducibility was statistically significantly superior to both manual outlining and FIRST after exclusion of failed segmentations.

学科与关键词

关键词
HippocampusManual segmentationAutomatic segmentationMagnetic resonance imagingMild cognitive impairmentAlzheimer's disease
相关
加载中…
  • Automated cross-sectional and longitudinal hippocampal volume measurement in mild cognitive impairment and Alzheimer's disease
    Leung, Kelvin K.*; Barnes, Josephine; Ridgway, Gerard R.; Bartlett, Jonathan W.; Clarkson, Matthew J.; Macdonald, Kate; Schuff, Norbert; Fox, Nick C.; Ourselin, SebastienNeuroImage, 2010, 51(4): 1345-1359.被引 200
  • Automated algorithm to measure changes in medial temporal lobe volume in Alzheimer disease
    Kazemifar, Samaneh; Drozd, John J.; Rajakumar, Nagalingam; Borrie, Michael J.; Bartha, Robert*Journal of Neuroscience Methods, 2014, 227: 35-46.被引 11
  • A comparison of manual tracing and FreeSurfer for estimating hippocampal volume over the adult lifespan
    Schmidt, Mike F.*; Storrs, Judd M.; Freeman, Kevin B.; Jack, Clifford R., Jr.; Turner, Stephen T.; Griswold, Michael E.; Mosley, Thomas H., Jr.HUMAN BRAIN MAPPING, 2018, 39(6): 2500-2513.被引 72
查看全部 →

发表信息

论文状态
公开发表
期刊
NeuroImage
发表日期
2014-05-15
卷期
第 92 卷
页码
169-181
DOI
10.1016/j.neuroimage.2014.01.058
语言
ENGLISH
期刊收录
SCIE
期刊等级
Q1
成果收录
SCIE
资助标注
"neuGRID4you" project from the European Commission's Seventh Framework Programme [283562]; Bristol-Myers Squibb; European Commission 6th and 7th Framework programmes; Joint Programme Initiative on Neurodegeneration; Zon-Mw; innovative Medicine Initiative, and Diagenic, Norway; Pfizer; Novartis; Merck Serono

作者

  • M

    Mulder, Emma R. (第一作者)

  • d

    de Jong, Remko A.

查看全部 8 位作者收起作者
  • K

    Knol, Dirk L.

  • v

    van Schijndel, Ronald A.

  • C

    Cover, Keith S.

  • V

    Visser, Pieter J.

  • B

    Barkhof, Frederik

  • V

    Vrenken, Hugo (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417