摘要
BACKGROUND: Peripartum cardiomyopathy, one of the most fatal conditions during delivery, results in heart failure secondary to left ventricu-lar systolic dysfunction. Left ventricular dysfunction can result in abnormali-ties in electrocardiography. However, the usefulness of electrocardiography in the identification of peripartum cardiomyopathy in pregnant women remains unclear.OBJECTIVE: This study aimed to evaluate the effectiveness of a 12-lead electrocardiography-based artificial intelligence/machine learning-based software as a medical device for screening peripartum cardiomyopathy.STUDY DESIGN: This retrospective cohort study included pregnant women who underwent transthoracic echocardiography between a month before and 5 months after delivery and underwent 12-lead electrocardiog-raphy within 30 days of echocardiography between December 2011 and May 2022 at Seoul National University Hospital. The performance of 12-lead electrocardiography-based artificial intelligence/machine learn-ing analysis (AiTiALVSD software; version 1.00.00, which was developed to screen for left ventricular systolic dysfunction in the general population) was evaluated for the identification of peripartum cardiomyopathy. In addi-tion, the performance of another artificial intelligence/machine learning algorithm using only 1-lead electrocardiography to detect left ventricular systolic dysfunction was evaluated in identifying peripartum cardiomyopa-thy. The results were obtained under a 95% confidence interval and considered significant when P<.05.RESULTS: Among the 14,557 women who delivered during the study period, 204 (1.4%) underwent transthoracic echocardiography a month before and 5 months after delivery. Among them, 12 (5.8%) were diagnosed with peripartum cardiomyopathy. The results showed that AiTiALVSD for 12-lead electrocardiography was highly effective in detect-ing peripartum cardiomyopathy, with an area under the receiver operating characteristic of 0.979 (95% confidence interval, 0.953-1.000), an area under the precision-recall curve of 0.715 (95% confidence interval, 0.499-0.951), a sensitivity of 0.917 (95% confidence interval, 0.760-1.000), a specificity of 0.927 (95% confidence interval, 0.890-0.964), a positive predictive value of 0.440 (95% confidence interval, 0.245-0.635), and a negative predictive value of 0.994 (95% confidence interval, 0.983-1.000). In addition, a 1-lead (lead I) artificial intelligence/machine learning algorithm showed excellent performance; the area under the receiver operating characteristic, area under the preci-sion-recall curve, sensitivity, specificity, positive predictive value, and neg-ative predictive value were 0.944 (95% confidence interval, 0.895 -0.993), 0.520 (95% confidence interval, 0.319-0.801), 0.833 (95% confidence interval, 0.622-1.000), 0.880 (95% confidence interval, 0.834-0.926), 0.303 (95% confidence interval, 0.146-0.460), and 0.988 (95% confidence interval, 0.972-1.000), respectively.CONCLUSION: The 12-lead electrocardiography-based artificial intelligence/machine learning-based software as a medical device (AiTiALVSD) and 1-lead algorithm are noninvasive and effective ways of identifying cardiomyopathies occurring during the peripartum period, and they could potentially be used as highly sensitive screening tools for peripartum cardiomyopathy.
学科与关键词
- Peripartum cardiomyopathy: the challenge of predicting cardiac function recoveryBasic, Carmen; Schaufelberger, Maria*European Heart Journal, 2024, 45(16): 1440-1442.被引 2
- Artificial Intelligence-Enabled Electrocardiography Predicts Left Ventricular Dysfunction and Future Cardiovascular Outcomes: A Retrospective AnalysisChen, Hung-Yi; Lin, Chin-Sheng; Fang, Wen-Hui; Lou, Yu-Sheng; Cheng, Cheng-Chung; Lee, Chia-Cheng; Lin, ChinJournal of Personalized Medicine, 2022, 12(3): 455.被引 11
- Development and Validation of Deep-Learning Algorithm for Electrocardiography-Based Heart Failure IdentificationKwon, Joon-myoung; Kim, Kyung-Hee*; Jeon, Ki-Hyun; Kim, Hyue Mee; Kim, Min Jeong; Lim, Sung-Min; Song, Pil Sang; Park, Jinsik; Choi, Rak Kyeong; Oh, Byung-HeeKorean Circulation Journal, 2019, 49(7): 629-639.被引 69
