ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Electrocardiogram-based deep learning model to screen peripartum cardiomyopathy

Jung, Young Mi; Kang, Sora; Son, Jeong Min; Lee, Hak Seung; Han, Ga In; Yoo, Ah-Hyun; Kwon, Joon-myoung; Park, Chan-Wook; Park, Joong Shin; Jun, Jong Kwan; Lee, Min Sung*; Lee, Seung Mi*
AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM2023-12DOI: 10.1016/j.ajogmf.2023.101184
1被引3阅读
引用收藏
分享

摘要

BACKGROUND: Peripartum cardiomyopathy, one of the most fatal conditions during delivery, results in heart failure secondary to left ventricu-lar systolic dysfunction. Left ventricular dysfunction can result in abnormali-ties in electrocardiography. However, the usefulness of electrocardiography in the identification of peripartum cardiomyopathy in pregnant women remains unclear.OBJECTIVE: This study aimed to evaluate the effectiveness of a 12-lead electrocardiography-based artificial intelligence/machine learning-based software as a medical device for screening peripartum cardiomyopathy.STUDY DESIGN: This retrospective cohort study included pregnant women who underwent transthoracic echocardiography between a month before and 5 months after delivery and underwent 12-lead electrocardiog-raphy within 30 days of echocardiography between December 2011 and May 2022 at Seoul National University Hospital. The performance of 12-lead electrocardiography-based artificial intelligence/machine learn-ing analysis (AiTiALVSD software; version 1.00.00, which was developed to screen for left ventricular systolic dysfunction in the general population) was evaluated for the identification of peripartum cardiomyopathy. In addi-tion, the performance of another artificial intelligence/machine learning algorithm using only 1-lead electrocardiography to detect left ventricular systolic dysfunction was evaluated in identifying peripartum cardiomyopa-thy. The results were obtained under a 95% confidence interval and considered significant when P<.05.RESULTS: Among the 14,557 women who delivered during the study period, 204 (1.4%) underwent transthoracic echocardiography a month before and 5 months after delivery. Among them, 12 (5.8%) were diagnosed with peripartum cardiomyopathy. The results showed that AiTiALVSD for 12-lead electrocardiography was highly effective in detect-ing peripartum cardiomyopathy, with an area under the receiver operating characteristic of 0.979 (95% confidence interval, 0.953-1.000), an area under the precision-recall curve of 0.715 (95% confidence interval, 0.499-0.951), a sensitivity of 0.917 (95% confidence interval, 0.760-1.000), a specificity of 0.927 (95% confidence interval, 0.890-0.964), a positive predictive value of 0.440 (95% confidence interval, 0.245-0.635), and a negative predictive value of 0.994 (95% confidence interval, 0.983-1.000). In addition, a 1-lead (lead I) artificial intelligence/machine learning algorithm showed excellent performance; the area under the receiver operating characteristic, area under the preci-sion-recall curve, sensitivity, specificity, positive predictive value, and neg-ative predictive value were 0.944 (95% confidence interval, 0.895 -0.993), 0.520 (95% confidence interval, 0.319-0.801), 0.833 (95% confidence interval, 0.622-1.000), 0.880 (95% confidence interval, 0.834-0.926), 0.303 (95% confidence interval, 0.146-0.460), and 0.988 (95% confidence interval, 0.972-1.000), respectively.CONCLUSION: The 12-lead electrocardiography-based artificial intelligence/machine learning-based software as a medical device (AiTiALVSD) and 1-lead algorithm are noninvasive and effective ways of identifying cardiomyopathies occurring during the peripartum period, and they could potentially be used as highly sensitive screening tools for peripartum cardiomyopathy.

学科与关键词

关键词
artificial intelligence/machine learning modelelectrocardi-ographyheart diseaseleft ventricular systolic dysfunctionperipartum cardiomyopathy
相关
加载中…
  • Peripartum cardiomyopathy: the challenge of predicting cardiac function recovery
    Basic, Carmen; Schaufelberger, Maria*European Heart Journal, 2024, 45(16): 1440-1442.被引 2
  • Artificial Intelligence-Enabled Electrocardiography Predicts Left Ventricular Dysfunction and Future Cardiovascular Outcomes: A Retrospective Analysis
    Chen, Hung-Yi; Lin, Chin-Sheng; Fang, Wen-Hui; Lou, Yu-Sheng; Cheng, Cheng-Chung; Lee, Chia-Cheng; Lin, ChinJournal of Personalized Medicine, 2022, 12(3): 455.被引 11
  • Development and Validation of Deep-Learning Algorithm for Electrocardiography-Based Heart Failure Identification
    Kwon, Joon-myoung; Kim, Kyung-Hee*; Jeon, Ki-Hyun; Kim, Hyue Mee; Kim, Min Jeong; Lim, Sung-Min; Song, Pil Sang; Park, Jinsik; Choi, Rak Kyeong; Oh, Byung-HeeKorean Circulation Journal, 2019, 49(7): 629-639.被引 69
查看全部 →

发表信息

论文状态
公开发表
期刊
AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM
发表日期
2023-12
卷期
第 5 卷, 第 12 期
页码
101184
DOI
10.1016/j.ajogmf.2023.101184
成果收录
SCIE
资助标注
Medical AI Co Ltd; Seoul National University Hospital research fund [0620223400]

作者

  • J

    Jung, Young Mi (第一作者)

  • K

    Kang, Sora

查看全部 12 位作者收起作者
  • S

    Son, Jeong Min

  • L

    Lee, Hak Seung

  • H

    Han, Ga In

  • Y

    Yoo, Ah-Hyun

  • K

    Kwon, Joon-myoung

  • P

    Park, Chan-Wook

  • P

    Park, Joong Shin

  • J

    Jun, Jong Kwan

  • L

    Lee, Min Sung (通讯)

  • L

    Lee, Seung Mi (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417