ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Individualized CT Angiography Protocols for the Evaluation of the Aorta: A Feasibility Study

Kok, Madeleine; de Haan, Michael W.; Mihl, Casper; Eijsvoogel, Nienke G.; Hendriks, Babs M. F.; Sailer, Anna M.; Derks, Kris; Schnerr, Roald S.; Schurink, Geert Willem H.; Wildberger, Joachim E.; Das, Marco*
Journal of Vascular and Interventional Radiology2016-4DOI: 10.1016/j.jvir.2016.01.009
11被引2阅读
引用收藏
分享

摘要

Purpose: Ionizing radiation and iodinated contrast media are potential drawbacks to repetitive follow-up CT angiography in current practice. The aim of the present study was to optimize radiation dose and contrast agent volume by using individualized CT angiography protocols. Materials and Methods: Eighty consecutive patients referred for CT angiography of the whole aorta were prospectively evaluated. Patients were divided into groups of patients with a body mass index (BMI) < 28 kg/m(2) (group 1; n = 50) and those with a BMI >= 28 kg/m(2) (group 2; n = 30). A control group consisted of 50 consecutive patients who were retrospectively evaluated. CT angiography parameters on a second-generation dual-source scanner were 128 x 0.6-mm collimation, pitch of 0.9, rotation time of 0.33 seconds, tube voltages of 80/100/120 kVp (group 1/group 2/control), reference tube current of 400 mA, and image reconstruction at 1-mm/0.8-mm slice thickness (kernels, B30f [control] and I30f/strength 3 [groups 1/2]). The control group received 120 mL of contrast agent (300 mgI/mL) at 4.8 mL/s; groups 1 and 2 received 44 mL and 53 mL at 3.3 mL/s and 4 mL/s, respectively. Effective dose was evaluated for each patient. Image quality was determined by qualitative image analysis at the levels of the thoracic; abdominal, and pelvic aorta as nondiagnostic, diagnostic, good, or excellent, and quantitative image analysis was performed, including attenuation values and contrast-to-noise ratio (CNR). Results: Mean effective radiation dose values for CT angiography of the aorta were 3.7 mSv +/- 0.7 in group 1, 6.7 mSv +/- 1.4 in group 2, and 8.7 mSv +/- 1.9 in the control group (P < .001). Mean attenuation values and CNR levels were 334 HU +/- 66 and 16 8, respectively, in group 1, 277 HU 56 and 14 5 in group 2, and 305 HU 77 and 11 4 in the control group. Conclusions: Iterative reconstruction algorithms resulted in 23%-57% less radiation in combination with 55%-63% less contrast agent volume compared with standard CT protocols.

学科与关键词

关键词
AFFIRMED ITERATIVE RECONSTRUCTIONCOMPUTED-TOMOGRAPHY ANGIOGRAPHYIMAGE QUALITYCONTRAST-MEDIUMPRACTICE GUIDELINESCLINICAL-PRACTICEOBESE-PATIENTSENHANCEMENT
相关
加载中…
  • Low dose dual-source CT angiography of the thoracic aorta
    Farrelly, Cormac*; Davarpanah, Amir; Keeling, Aoife N.; Sheehan, John; Ragin, Ann; Yaghmai, Vahid; Carr, James C.International Journal of Cardiovascular Imaging, 2011, 27(7): 1025-1034.被引 12
  • Image quality assessment of artificial intelligence iterative reconstruction for low dose aortic CTA: A feasibility study of 70 kVp and reduced contrast medium volume
    Li, Wanjiang; You, Yongchun; Zhong, Sihua; Shuai, Tao; Liao, Kai; Yu, Jianqun; Zhao, Jin; Li, Zhenlin; Lu, Chunyan*EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149: 110221.被引 18
  • Adaptation of Contrast Injection Protocol to Tube Potential for Cardiovascular CT
    Wang, Yajuan; Bolen, Michael; Sydow, Gregg; Kottha, Anjali; Soufan, Kassem; Bullen, Jennifer; Kemper, Corey; Kalafut, John; Halliburton, Sandra S.*American Journal of Roentgenology, 2014, 203(6): 1181-1191.被引 4
查看全部 →

发表信息

论文状态
公开发表
期刊
Journal of Vascular and Interventional Radiology
发表日期
2016-04
卷期
第 27 卷, 第 4 期
页码
531-538
DOI
10.1016/j.jvir.2016.01.009
语言
ENGLISH
成果收录
SCIE
资助标注
Siemens (Forchheim, Germany); Philips (Best, The Netherlands); Bayer (Leverkusen, Germany); AGFA Healthcare (Rijswijk, The Netherlands); Siemens; Bayer; Philips

作者

  • K

    Kok, Madeleine (第一作者)

  • d

    de Haan, Michael W.

查看全部 11 位作者收起作者
  • M

    Mihl, Casper

  • E

    Eijsvoogel, Nienke G.

  • H

    Hendriks, Babs M. F.

  • S

    Sailer, Anna M.

  • D

    Derks, Kris

  • S

    Schnerr, Roald S.

  • S

    Schurink, Geert Willem H.

  • W

    Wildberger, Joachim E.

  • D

    Das, Marco (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417