ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Adaptation of Contrast Injection Protocol to Tube Potential for Cardiovascular CT

Wang, Yajuan; Bolen, Michael; Sydow, Gregg; Kottha, Anjali; Soufan, Kassem; Bullen, Jennifer; Kemper, Corey; Kalafut, John; Halliburton, Sandra S.*
American Journal of Roentgenology2014-12DOI: 10.2214/AJR.13.12013
4被引7阅读
引用收藏
分享

摘要

OBJECTIVE. The purpose of this study was to investigate and validate adaptation of a cardiovascular CT angiography contrast injection protocol for lower tube potential. MATERIALS AND METHODS. Eighty-three patients evaluated for thoracic aortic disease with a 256-MDCT scanner were imaged at 120 kV (group 1) or 100 kV (group 2) with the same contrast protocol (90 mL iopromide 370 mg I/mL at 3.5 mL/s). A pharmacokinetic model was validated and used to simulate aortic attenuation in group 2 patients with 20%, 33%, and 44% reduction in contrast volume. A 44% volume reduction was applied to 50 additional patients who underwent imaging at 100 kV (group 3). Patient characteristics, scanning and radiation parameters, and objective and subjective image indexes were compared among groups. RESULTS. Group 2 patients had higher mean aortic blood attenuation (399 +/- 61 HU) than group 1 patients (281 +/- 48 HU) (p < 0.001) but similar image noise. Group 3 and group 1 patients had similar mean aortic attenuation and noise. Subjective assessment of image quality indicated that group 3 and group 1 had comparable percentages of images with good or excellent diagnostic confidence scores (reader 1, 98% vs 96%; reader 2, 96% vs 96%). CONCLUSION. Lower tube potential (100 kV) for cardiothoracic CT could be accompanied by a 44% reduction in contrast volume with satisfactory aortic blood-pool attenuation in most patients. More personalized adaptation of the contrast protocol that takes into account patient characteristics and tube potential is necessary to ensure sufficient contrast enhancement for all patients.

学科与关键词

关键词
cardiovascular CTcontrast dosecontrast injection protocolradiation dosetube potential
相关
加载中…
  • Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients
    Kok, Madeleine*; Mihl, Casper; Hendriks, Babs M. F.; Altintas, Sibel; Kietselaer, Bas L. J. H.; Wildberger, Joachim E.; Das, MarcoEUROPEAN JOURNAL OF RADIOLOGY, 2016, 85(6): 1068-1074.被引 41
  • Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol
    Albrecht, Moritz H.; Nance, John W.; Schoepf, U. Joseph*; Jacobs, Brian E.; Bayer, Richard R., II; Litwin, Sheldon E.; Reynolds, Michael A.; Otani, Katharina; Mangold, Stefanie; Varga-Szemes, Akos; De Santis, Domenico; Eid, Marwen; Apfaltrer, Georg; Tesche, Christian; Goeller, Markus; Vogl, Thomas J.; De Cecco, Carlo N.European Radiology, 2018, 28(5): 2134-2142.被引 20
  • Low kV and Low Concentration Contrast Agent with Iterative Reconstruction of Computed Tomography (CT) Coronary Angiography: A Preliminary Study
    Zhang, Hong*; Ma, Yanhe; Lyu, Jun; Yang, Yapeng; Yuan, Wei; Song, ZhenchunMEDICAL SCIENCE MONITOR, 2017, 23: 5005-5010.被引 7
查看全部 →

发表信息

论文状态
公开发表
期刊
American Journal of Roentgenology
发表日期
2014-12
卷期
第 203 卷, 第 6 期
页码
1181-1191
DOI
10.2214/AJR.13.12013
语言
ENGLISH
期刊收录
SCIE
期刊等级
Q2
成果收录
SCIE
资助标注
Bayer HealthCare

作者

  • W

    Wang, Yajuan (第一作者)

  • B

    Bolen, Michael

查看全部 9 位作者收起作者
  • S

    Sydow, Gregg

  • K

    Kottha, Anjali

  • S

    Soufan, Kassem

  • B

    Bullen, Jennifer

  • K

    Kemper, Corey

  • K

    Kalafut, John

  • H

    Halliburton, Sandra S. (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417