Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients

Kok, Madeleine*; Mihl, Casper; Hendriks, Babs M. F.; Altintas, Sibel; Kietselaer, Bas L. J. H.; Wildberger, Joachim E.; Das, Marco
EUROPEAN JOURNAL OF RADIOLOGY2016-6DOI: 10.1016/j.ejrad.2016.03.022
41被引10阅读
引用收藏
分享

摘要

Purpose: The purpose was to investigate optimal contrast media (CM) injection parameters for lower kVp settings, whilst maintaining diagnostic attenuation levels. Methods and materials: First, a circulation phantom with physiological parameters (BP 120/80 mmHg, HR 60 bpm) was used. A fixed CM injection protocol was used for each kVp setting (300 mgI/m1 [Iopromide], volume =45 ml, flow rate = 6.0 ml/s, iodine delivery rate [IDR] = 1.8 gI/s, iodine load = 13.5 gI; at 120, 100, 80 and 70 kVp). Then, IDR was decreased by steps of 0.2 gI/s for each kVp setting, until diagnostically insufficient attenuation values were reached (<325 HU). In order to keep injection time constant (7.5 s), total iodine load (TIL) was reduced accordingly. Second, clinical applicability at 120 and 100 kVp was evaluated in patients (n = 60) referred for coronary CT angiography. A standard and reduced (12% less) CM protocol was used based on weight classes and scan duration (`high-pitch': 1 s; 'adaptive sequence' and 'helical': 7 s). Attenuation levels of the coronary arteries were measured and compared between protocols. Results: Using a fixed CM injection at each kVp level resulted in the following HU values: 335 HU +/- 31 (120 kVp); 425 HU +/- 30 (100 kVp); 587 HU +/- 29 (80 kVp); 666 HU +/- 27 (70 kVp). Keeping diagnostic enhancement levels (353 HU +/- 28) CM could be reduced as follows: 12% for 100 kVp; 45% for 80 kVp and 56% for 70 kVp. Diagnostic enhancement levels could be reproduced with concurrent CM reduction (-12% at 100 kV) in the clinical setting (382 HU +/- 35). Conclusion: CM injection parameters can be substantially reduced at low kVp settings (up to 56% at 70 kVp), whilst maintaining diagnostic attenuation levels. This may play an important role in CT imaging of the coronary arteries as well as cerebral and peripheral circulations in the future.

学科与关键词

关键词
Multidetector-row computed tomographyContrast mediaTube voltage
相关
加载中…
  • Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol
    Albrecht, Moritz H.; Nance, John W.; Schoepf, U. Joseph*; Jacobs, Brian E.; Bayer, Richard R., II; Litwin, Sheldon E.; Reynolds, Michael A.; Otani, Katharina; Mangold, Stefanie; Varga-Szemes, Akos; De Santis, Domenico; Eid, Marwen; Apfaltrer, Georg; Tesche, Christian; Goeller, Markus; Vogl, Thomas J.; De Cecco, Carlo N.European Radiology, 2018, 28(5): 2134-2142.被引 20
  • Adaptation of Contrast Injection Protocol to Tube Potential for Cardiovascular CT
    Wang, Yajuan; Bolen, Michael; Sydow, Gregg; Kottha, Anjali; Soufan, Kassem; Bullen, Jennifer; Kemper, Corey; Kalafut, John; Halliburton, Sandra S.*American Journal of Roentgenology, 2014, 203(6): 1181-1191.被引 4
  • Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom
    De Santis, Domenico; Caruso, Damiano; Schoepf, U. Joseph*; Eid, Marwen; Albrecht, Moritz H.; Duguay, Taylor M.; Varga-Szemes, Akos; Laghi, Andrea; De Cecco, Carlo N.European Radiology, 2018, 28(8): 3473-3481.被引 16
查看全部 →

发表信息

论文状态
公开发表
期刊
EUROPEAN JOURNAL OF RADIOLOGY
发表日期
2016-06
卷期
第 85 卷, 第 6 期
页码
1068-1074
DOI
10.1016/j.ejrad.2016.03.022
语言
ENGLISH
成果收录
SCIE
资助标注
Siemens; Bayer; Philips; GE

作者

  • K

    Kok, Madeleine (通讯) (第一作者)

  • M

    Mihl, Casper

查看全部 7 位作者收起作者
  • H

    Hendriks, Babs M. F.

  • A

    Altintas, Sibel

  • K

    Kietselaer, Bas L. J. H.

  • W

    Wildberger, Joachim E.

  • D

    Das, Marco

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417