ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective

Zhang, Long-Jiang; Wu, Sheng-Yong; Wang, Jing; Lu, Ying; Zhang, Zhuo-Li; Jiang, Shi-Sen; Zhou, Chang-Sheng; Lu, Guang-Ming*南京大学
Acta Radiologica2010-9DOI: 10.3109/02841851.2010.492792
35被引9阅读
引用收藏
分享

摘要

Background: Dual-source CT coronary angiography (CTCA) has been used to detect coronary artery disease; however, the factors with potential to affect its diagnostic accuracy remain to be defined. Purpose: To prospectively evaluate the accuracy of dual-source CTCA in diagnosing coronary artery stenosis according to conventional coronary angiography (CAG), and the effect of average heart rate, heart rate variability, and calcium score on the accuracy of CTCA. Material and Methods: A total of 113 patients underwent both dual-source CTCA and CAG. The results were used to evaluate the findings in dual-source CTCA to assess the accuracy in the diagnosis of >50% (significant stenosis) and >75% (severe stenosis) of coronary artery according to those by CAG. Patients were divided into subgroups according to their heart rate (HR), HR variability (HRV), and calcium score, and the accuracy of CTCA was further evaluated. The chi-square test was used to analyze the difference in sensitivity and specificity for the detection of >50% and >75% coronary stenosis among subgroups. The generalized estimation equation method was used in per-vessel analysis to adjust for within-patient correlation. Results: In all, 113 patients had 338 vessels and 1661 segments evaluated by CAG. Dual-source CTCA displayed 1527 segments (91.9%). Among them, 1468 segments (calcium score by CAG score 1, n=1018; score 2, n=270; score 3, n=180) were assessable in CTCA. On a per-patient analysis, the sensitivity and specificity of CTCA were 93.9% and 93.5% for significant stenosis and 86.9% and 98.1% for severe stenosis. On a per-vessel basis, the sensitivity and specificity were 90.2% and 97.1% for significant and 83.3% and 98.1% for severe stenosis. On a per-segment analysis, the sensitivity and specificity were 90.2% and 97.1% for significant and 83.3% and 98.1% for severe stenosis. Average HR had no effect on the sensitivity and specificity of CTCA (P>0.05); whereas HRV and calcium score had some effect on the sensitivity and specificity of CTCA (P<0.05). Conclusion: On a per-patient, per-vessel, and per-segment basis, dual-source CTCA has a high sensitivity and specificity for the diagnosis of coronary artery stenosis. Average HR has no effect on the diagnostic accuracy of CTCA, while HRV and calcium score have a statistically significant effect on the sensitivity and specificity of CTCA.

学科与关键词

关键词
Coronary artery diseasetomographyX-ray computedCT angiography
相关
加载中…
  • Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography
    Fang, Xiang Ming; Chen, Hong Wei*; Hu, Xiao Yun; Bao, Jian; Chen, Yin; Yang, Zhen Yu; Buckley, Orla; Wu, Xiao QingInternational Journal of Cardiovascular Imaging, 2010, 26(3): 323-331.被引 19
  • Efficacy of dual-source CT coronary angiography in evaluating coronary stenosis: initial experience
    Chen, Hong-wei; Fang, Xiang-ming*; Hu, Xiao-yun; Bao, Jian; Hu, Chun-hong; Chen, Yin; Yang, Zhen-yu; Alexander, Lerner; Wu, Xiao-qingCLINICAL IMAGING, 2010, 34(3): 165-171.被引 9
  • Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols
    Neefjes, Lisan A.; Rossi, Alexia; Genders, Tessa S. S.; Nieman, Koen; Papadopoulou, Stella L.; Dharampal, Anoeshka S.; Schultz, Carl J.; Weustink, Annick C.; Dijkshoorn, Marcel L.; ten Kate, Gert-Jan R.; Dedic, Admir; van Straten, Marcel; Cademartiri, Filippo; Hunink, M. G. Myriam; Krestin, Gabriel P.; de Feyter, Pim J.; Mollet, Nico R.*European Radiology, 2013, 23(3): 614-622.被引 24
查看全部 →

发表信息

论文状态
公开发表
期刊
Acta Radiologica
发表日期
2010-09
卷期
第 51 卷, 第 7 期
页码
727-740
DOI
10.3109/02841851.2010.492792
语言
ENGLISH
成果收录
SCIE
资助标注
National Science & Technology Pillar Program [2007BAI05B01]

作者

  • Z

    Zhang, Long-Jiang (第一作者)

    nanjing univ

  • W

    Wu, Sheng-Yong

查看全部 8 位作者收起作者
  • W

    Wang, Jing

    nanjing univ

  • L

    Lu, Ying

  • Z

    Zhang, Zhuo-Li

    nanjing univ

  • J

    Jiang, Shi-Sen

    nanjing univ

  • Z

    Zhou, Chang-Sheng

    nanjing univ

  • L

    Lu, Guang-Ming (通讯)

    nanjing univ

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417