ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Radiation dose values for various coronary calcium scoring protocols in dual-source CT

Stolzmann, Paul; Leschka, Sebastian; Betschart, Thomas; Desbiolles, Lotus; Flohr, Thomas G.; Marincek, Borut; Alkadhi, Hatem*
International Journal of Cardiovascular Imaging2009-4DOI: 10.1007/s10554-008-9397-y
10被引6阅读
引用收藏
分享

摘要

Purpose The purpose of this study was to assess the radiation dose and associated image noise of previously suggested calcium scoring protocols using dual-source CT. Methods One hundred consecutive patients underwent coronary calcium scoring using dual-source CT. Patients were randomly assigned to five different protocols: retrospective ECG-gating and tube current reduction to 4% outside the pulsing window at 120 (protocol A) and 100 kV (B), prospective ECG-triggering at 120 (C) and 100 kV (D), and prospective ECG-triggering at 100 kV with attenuation-based tube current modulation (E). Radiation dose parameters and image noise were determined and compared. Results Protocol A resulted in an effective dose of 1.3 +/- A 0.2 mSv, protocol B in 0.8 +/- A 0.2 mSv, protocol C in 1.0 +/- A 0.2 mSv, protocol D in 0.6 +/- A 0.1 mSv, and protocol E in 0.7 +/- A 0.1 mSv. Effective doses were significantly lower (P < 0.001) with 100 kV when compared to 120 kV protocols, and were significantly lower (P < 0.001) for prospective versus retrospective ECG-gating. No significant difference was found between protocol D and E. Significant negative correlations were found between the CTDIvol and heart rate for both retrospective ECG-gating protocols (protocol A: r = -0.98, P < 0.001; protocol B: r = -0.83, P < 0.001). The mean image noise was 29.0 +/- A 6.7 HU, with no significant differences between the five protocols. The image noise was significantly correlated with the body weight (r = 0.21, P < 0.05) and BMI (r = 0.31, P < 0.01). Conclusions Effective dose of calcium scoring using dual-source CT ranges from 0.6 to 1.3 mSv. Prospective triggering and lower tube voltage significantly reduces the radiation but yield similar image noise.

学科与关键词

关键词
Coronary calcium scoringDual-source computed tomographyRadiation dose
相关
加载中…

文献加载失败,请重试

重试

发表信息

论文状态
公开发表
期刊
International Journal of Cardiovascular Imaging
发表日期
2009-04
卷期
第 25 卷, 第 4 期
页码
443-451
DOI
10.1007/s10554-008-9397-y
语言
ENGLISH
成果收录
SCIE
资助标注
Swiss National Science Foundation

作者

  • S

    Stolzmann, Paul (第一作者)

  • L

    Leschka, Sebastian

查看全部 7 位作者收起作者
  • B

    Betschart, Thomas

  • D

    Desbiolles, Lotus

  • F

    Flohr, Thomas G.

  • M

    Marincek, Borut

  • A

    Alkadhi, Hatem (通讯)

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417