Closing in on the K Edge: Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System

Meyer, Mathias*; Haubenreisser, Holger; Schoepf, U. Joseph; Vliegenthart, Rozemarijn; Leidecker, Christianne; Allmendinger, Thomas; Lehmann, Ralf; Sudarski, Sonja; Borggrefe, Martin; Schoenberg, Stefan O.; Henzler, Thomas
RADIOLOGY2014-11DOI: 10.1148/radiol.14140244
152被引5阅读
引用收藏
分享

摘要

Purpose: To prospectively evaluate radiation and contrast medium requirements for performing high-pitch coronary computed tomographic (CT) angiography at 70 kV using a third-generation dual-source CT system in comparison to a second-generation dual-source CT system. Materials and Methods: All patients gave informed consent for this institutional review board-approved study. Forty-five patients (median age, 52 years; 27 men) were imaged in high-pitch mode with a third-generation dual-source CT system at 70 kV (n = 15) or with a second-generation dual-source CT system at 80 or 100 kV (n = 15 for each). Tube voltage was based on body mass index: 80 or 70 kV for less than 26 kg/m(2) versus 100 kV for 26-30 kg/m(2). For the 80- and 100-kV protocols, 80 mL of contrast material was injected, versus 45 mL for the 70-kV protocol. Data were reconstructed by using a second-generation iterative reconstruction algorithm for second-generation dual-source CT and a recently introduced third-generation iterative reconstruction algorithm for third-generation dual-source CT. Objective image quality was measured for various regions of interest, and subjective image quality was evaluated with a five-point Likert scale. Results: The signal-to-noise ratio of the coronary CT angiography studies acquired with 70 kV was significantly higher (70 kV: 14.3-17.6 vs 80 kV: 7.1-12.9 vs 100 kV: 9.8-12.9; P < .0497) than those acquired with the other two protocols for all coronary arteries. Qualitative image quality analyses revealed no significant differences between the three CT angiography protocols (median score, 5; P > .05). The mean effective dose was 75% and 108% higher (0.92 mSv +/- 0.3 [standard deviation] and 0.78 mSv +/- 0.2 vs 0.44 mSv +/- 0.1; P < .0001), respectively, for the 80- and 100-kV CT angiography protocols than for the 70-kV CT angiography protocol. Conclusion: In nonobese patients, third-generation high-pitch coronary dual-source CT angiography at 70 kV results in robust image quality for studying the coronary arteries, at significantly reduced radiation dose (0.44 mSv) and contrast medium volume (45 mL), thus enabling substantial radiation dose and contrast medium savings as compared with second-generation dual-source CT.

学科与关键词

关键词
IMAGE QUALITYITERATIVE RECONSTRUCTIONCOMPUTED-TOMOGRAPHYRADIATION-EXPOSURETUBE VOLTAGEPREVENTIONRISK
相关
加载中…
  • High-Pitch Coronary CT Angiography at 70 kVp With Low Contrast Medium Volume Comparison of 80 and 100 kVp High-Pitch Protocols
    Zhang, Long Jiang*; Qi, Li; De Cecco, Carlo N.; Zhou, Chang Sheng; Spearman, James V.; Schoepf, U. Joseph; Lu, Guang MingMedicine; analytical reviews of general medicine, neurology, psychiatry, dermatology, and pediatries, 2014, 93(22): e92.被引 30
  • Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose
    Leschka, Sebastian; Stolzmann, Paul; Schmid, Florian T.; Scheffel, Hans; Stinn, Bjoern; Marincek, Borut; Alkadhi, Hatem*; Wildermuth, SimonEuropean Radiology, 2008, 18(9): 1809-1817.被引 231
  • Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: An intraindividual comparison with sequential scanning at 120 kVp with 60 mL contrast agent
    Wang, Wei; Zhao, Yan E.; Qi, Li; Li, Xie; Zhou, Chang Sheng; Zhang, Long Jiang*; Lu, Guang Ming*EUROPEAN JOURNAL OF RADIOLOGY, 2017, 90: 97-105.被引 22
查看全部 →

发表信息

论文状态
公开发表
期刊
RADIOLOGY
发表日期
2014-11
卷期
第 273 卷, 第 2 期
页码
373-382
DOI
10.1148/radiol.14140244
语言
ENGLISH
期刊收录
SCIE
期刊等级
Q1
成果收录
SCIE
资助标注
Bayer; Bracco; GE; Medrad; Siemens

作者

  • M

    Meyer, Mathias (通讯) (第一作者)

  • H

    Haubenreisser, Holger

查看全部 11 位作者收起作者
  • S

    Schoepf, U. Joseph

  • V

    Vliegenthart, Rozemarijn

  • L

    Leidecker, Christianne

  • A

    Allmendinger, Thomas

  • L

    Lehmann, Ralf

  • S

    Sudarski, Sonja

  • B

    Borggrefe, Martin

  • S

    Schoenberg, Stefan O.

  • H

    Henzler, Thomas

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417