摘要
The intra- and inter-scanner variability of all automated method for MRI-based volumetry was investigated Using SPM5 algorithms and predefined masks derived from a probabilistic whole-brain atlas, this methods to determine the volumes of various brain structures (eg, hemispheres. lobes, cerebellum, basal allow ganglia. grey and white matter etc.) in single subjects in in observer-independent fashion. A healthy volunteer was scanned three times at six different MRI scanners (including different vendors and field strengths) to calculate intra- and inter-scanner volumetric coefficients of variation (CV). The mean intrascanner CV values per brain structure ranged from 0.50% to 4 4% (median, 0 89%). while the inter-scanner CV results varied between 0.66% and 14.7% (median, 4.74%) The overall (=combined intra- and inter-scanner) variability of measurements was only marginally higher, with CV results of 0.87-15.1% (median, 4 80%) Furthermore, the minimum percentage volume difference for detecting a significant volume change between two volume measurements in the same subject was calculated for each substructure For example, for the total brain volume, mean intra-scanner, inter-scanner. and overall CV results were 0.50%, 3.78%, and 3.80%, respectively, and the cut-offs for significant volume changes between two measurements in the same subject amounted to 1.4% for measurements on the same scanner and 10.5% oil different scanners. These findings may be useful for planning and assessing volumetric studies in neurological disea
学科与关键词
- Reproducibility of brain tissue volumes in longitudinal studies: Effects of changes in signal-to-noise ratio and scanner softwareShuter, Borys*; Yeh, Ing Berne; Graham, Steven; Au, Chris; Wang, Shih-ChangNeuroImage, 2008, 41(2): 371-379.被引 46
- Intra-and interscanner variability of magnetic resonance imaging based volumetry in multiple sclerosisBiberacher, Viola*; Schmidt, Paul; Keshavan, Anisha; Boucard, Christine C.; Righart, Ruthger; Saemann, Philipp; Preibisch, Christine; Froebel, Daniel; Aly, Lilian; Hemmer, Bernhard; Zimmer, Claus; Henry, Roland G.; Muehlau, MarkNeuroImage, 2016, 142: 479-488.被引 68
- Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based MethodGoto, Masami*; Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, KuniKOREAN JOURNAL OF RADIOLOGY, 2012, 13(4): 391-402.被引 16