摘要
Objective: Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Materials and Methods: Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction Levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 x [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. Results: A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. Conclusion: The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.
学科与关键词
- Effects of Gradient Non-Linearity Correction and Intensity Non-Uniformity Correction in Longitudinal Studies Using Structural Image Evaluation Using Normalization of Atrophy (SIENA)Takao, Hidemasa*; Abe, Osamu; Hayashi, Naoto; Kabasawa, Hiroyuki; Ohtomo, KuniJournal of Magnetic Resonance Imaging, 2010, 32(2): 489-492.被引 19
- Intra- and interscanner variability of automated voxel-based volumetry based on a 3D probabilistic atlas of human cerebral structuresHuppertz, Hans-Juergen*; Kroell-Seger, Judith; Kloeppel, Stefan; Ganz, Reinhard E.; Kassubek, JanNeuroImage, 2010, 49(3): 2216-2224.被引 118
- A robust method to estimate the intracranial volume across MRI field strengths (1.5T and 3T)Keihaninejad, Shiva; Heckemann, Rolf A.; Fagiolo, Gianlorenzo; Symms, Mark R.; Hajnal, Joseph V.; Hammers, Alexander*NeuroImage, 2010, 50(4): 1427-1437.被引 102