Diagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Software: IDx-DR and RetCAD

Grzybowski, Andrzej*; Brona, Piotr; Krzywicki, Tomasz; Ruamviboonsuk, Paisan
Ophthalmology and Therapy2025-1DOI: 10.1007/s40123-024-01049-z
6阅读
引用收藏
分享

摘要

Introduction: Automated diabetic retinopathy (DR) screening using artificial intelligence has the potential to improve access to eye care by enabling large-scale screening. However, little is known about differences in real-world performance between available algorithms. This study compares the diagnostic accuracy of two AI screening platforms, IDx-DR and RetCAD, for detecting referable diabetic retinopathy (RDR). Methods: Retinal images from 758 patients with diabetes were collected during screening from various clinics in Poland. Each patient was graded by three graders with 320 patients graded by Polish and 438 patients graded by Indian graders, with the majority decision serving as the reference standard. The images were evaluated independently by the IDx-DR and RetCAD algorithms. Sensitivity, specificity, positive and negative predictive values, and agreement between algorithms and human graders were calculated and statistically compared. Results: IDx-DR demonstrated higher sensitivity of 99.3% but lower specificity of 68.9% for RDR detection compared to RetCAD which had 89.4% sensitivity and 94.8% specificity. The positive predictive value was higher for RetCAD (96.4% vs 48.1% for IDx-DR) while the negative predictive value was higher for IDx-DR (99.5% vs 83.1% for RetCAD). Both algorithms achieved high sensitivity (> 95%) for sight-threatening diabetic retinopathy detection. Conclusion: In this direct comparison using the same patient cohort, the two algorithms showed differences in their operating parameters for RDR screening. IDx-DR prioritized avoiding false negatives over false positives while RetCAD maintained a more balanced trade-off. These results highlight the variable performance of current artificial intelligence screening solutions and suggest the importance of considering algorithm performance metrics when deploying automated diabetic retinopathy screening programs, based on available healthcare resources.

学科与关键词

关键词
Diabetic retinopathyArtificial intelligenceImageDiagnosticScreening
相关
加载中…
  • Evaluating the efficacy of AI systems in diabetic retinopathy detection: A comparative analysis of Mona DR and IDx-DR
    Grzybowski, Andrzej; Peeters, Freya; Barao, Rafael Correia; Brona, Piotr; Rommes, Stef; Krzywicki, Tomasz; Stalmans, Ingeborg*; Jacob, JulieActa Ophthalmologica, 2024.
  • Artificial intelligence-based screening for diabetic retinopathy at community hospital
    He, Jie; Cao, Tingyi; Xu, Feiping; Wang, Shasha; Tao, Haiqi; Wu, Tao; Sun, Liyan; Chen, Jili*Eye, 2020, 34(3): 572-576.被引 42
  • Simultaneous screening and classification of diabetic retinopathy and age-related macular degeneration based on fundus photos-a prospective analysis of the RetCAD system
    Skevas, Christos*; Weindler, Hanah; Levering, Max; Engelberts, Jonne; van Grinsven, Mark; Katz, ToamINTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15(12): 1985-1993.被引 4
查看全部 →

发表信息

论文状态
公开发表
期刊
Ophthalmology and Therapy
发表日期
2025-01
卷期
第 14 卷, 第 1 期
页码
73-84
DOI
10.1007/s40123-024-01049-z
成果收录
SCIE

作者

  • G

    Grzybowski, Andrzej (通讯) (第一作者)

  • B

    Brona, Piotr

查看全部 4 位作者收起作者
  • K

    Krzywicki, Tomasz

  • R

    Ruamviboonsuk, Paisan

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417