Evaluating the efficacy of AI systems in diabetic retinopathy detection: A comparative analysis of Mona DR and IDx-DR

Grzybowski, Andrzej; Peeters, Freya; Barao, Rafael Correia; Brona, Piotr; Rommes, Stef; Krzywicki, Tomasz; Stalmans, Ingeborg*; Jacob, Julie
Acta Ophthalmologica2024-12-10DOI: 10.1111/aos.17428
3阅读
引用收藏
分享

摘要

PurposeTo compare two artificial intelligence (AI)-based Automated Diabetic Retinopathy Image Assessment (ARIA) softwares in terms of concordance with specialist human graders and referable diabetic retinopathy (DR) diagnostic capacity.MethodsRetrospective comparative study including 750 consecutive diabetes mellitus patients imaged for non-mydriatic fundus photographs. For each patient four images (45 degrees field of view) were captured, centered on the optic disc and macula. Images were manually graded for severity of DR as no DR, any DR (mild non-proliferative diabetic retinopathy [NPDR] or more), referable DR (RDR (more than mild DR)), or sight-threatening DR (severe NPDR or more severe disease and/or clinically significant diabetic macular edema [CSDME]). IDx-DR and MONA DR output was compared with manual grading and with each other.ResultsTotal sample size was 750 patients, of which 55 were excluded due to ungradable images. Out of the remaining 695 patients 522 (75%) were considered as having no DR by manual consensus grading, and 106 (15%) as having RDR. Agreement between raters varied between moderate to substantial. IDx-DR showed moderate agreement with human grading (k = 0.4285) while MONA DR had substantial agreement (k = 0.6797). Out of 106 patients with a ground truth of RDR, IDx-DR identified 105 and MONA DR identified 99. The sensitivity and specificity rates for RDR detection of IDx-DR were 99.1 and 71.5% compared with MONA DR of 93.4 and 89.3% respectively. Of note, both ARIAs had 100% sensitivity for the detection of STDR.ConclusionBoth ARIAs performed well in this study population, both with sensitivity for RDR screening over 90%, with IDx-DR showing higher sensitivity and MONA DR higher specificity. MONA DR showed superior agreement with human certified graders.

学科与关键词

关键词
artificial intelligencediabetic retinopathymachine learningophthalmology
相关
加载中…
  • Diagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Software: IDx-DR and RetCAD
    Grzybowski, Andrzej*; Brona, Piotr; Krzywicki, Tomasz; Ruamviboonsuk, PaisanOphthalmology and Therapy, 2025, 14(1): 73-84.
  • Artificial intelligence-based screening for diabetic retinopathy at community hospital
    He, Jie; Cao, Tingyi; Xu, Feiping; Wang, Shasha; Tao, Haiqi; Wu, Tao; Sun, Liyan; Chen, Jili*Eye, 2020, 34(3): 572-576.被引 42
  • Performance of the AIDRScreening system in detecting diabetic retinopathy in the fundus photographs of Chinese patients: a prospective, multicenter, clinical study
    Yang, Yao; Pan, Jianying; Yuan, Miner; Lai, Kunbei; Xie, Huirui; Ma, Li; Xu, Suzhong; Deng, Ruzhi; Zhao, Mingwei; Luo, Yan*; Lin, Xiaofeng*Annals of Translational Medicine, 2022, 10(20): 1088.被引 9
查看全部 →

发表信息

论文状态
公开发表
期刊
Acta Ophthalmologica
发表日期
2024-12-10
DOI
10.1111/aos.17428
语言
ENGLISH
成果收录
SCIE

作者

  • G

    Grzybowski, Andrzej (第一作者)

  • P

    Peeters, Freya

查看全部 8 位作者收起作者
  • B

    Barao, Rafael Correia

  • B

    Brona, Piotr

  • R

    Rommes, Stef

  • K

    Krzywicki, Tomasz

  • S

    Stalmans, Ingeborg (通讯)

  • J

    Jacob, Julie

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417