ScholarMate
English简体中文繁體中文
客服热线:400-1616-289
登录注册
期刊论文

Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3rd generation dual-source CT

Mangold, Stefanie; Wichmann, Julian L.; Schoepf, U. Joseph*; Poole, Zachary B.; Canstein, Christian; Varga-Szemes, Akos; Caruso, Damiano; Bamberg, Fabian; Nikolaou, Konstantin; De Cecco, Carlo N.
European Radiology2016-10DOI: 10.1007/s00330-015-4191-4
33被引4阅读
引用收藏
分享

摘要

To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3(rd) generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p aeyen .0516), whereas image noise was rated significantly higher at 70 kV compared to aeyen100 kV (all p < .0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p aeyen .0829). Mean ED at 70-120 kV was 1.5 +/- 1.2 mSv, 2.4 +/- 1.5 mSv, 3.6 +/- 2.7 mSv, 5.9 +/- 4.0 mSv, 7.9 +/- 4.2 mSv, and 10.7 +/- 4.1 mSv, respectively (all p aecurrency sign .0414). Correlation analysis showed a moderate association between tube voltage and BMI (r = .639). ATVS allows individual tube voltage adaptation for CCTA performed with 3(rd) generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. aEuro cent Automated tube voltage selection allows an individual tube voltage adaption in CCTA. aEuro cent A tube voltage-based reduction of contrast medium volume is feasible. aEuro cent Image quality was maintained while radiation exposure was significantly decreased. aEuro cent A moderate association between tube voltage and body mass index was found.

学科与关键词

关键词
Coronary CT angiographyAutomated tube voltage selectionImage qualityBody mass indexRadiation dose reduction
相关
加载中…
  • Effect of Automated Attenuation-based Tube Voltage Selection on Radiation Dose at CT: An Observational Study on a Global Scale
    Spearman, James V.; Schoepf, U. Joseph*; Rottenkolber, Marietta; Driesser, Ivo; Canstein, Christian; Thierfelder, Kolja M.; Krazinski, Aleksander W.; De Cecco, Carlo N.; Meinel, Felix G.RADIOLOGY, 2016, 279(1): 167-174.被引 39
  • Closing in on the K Edge: Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System
    Meyer, Mathias*; Haubenreisser, Holger; Schoepf, U. Joseph; Vliegenthart, Rozemarijn; Leidecker, Christianne; Allmendinger, Thomas; Lehmann, Ralf; Sudarski, Sonja; Borggrefe, Martin; Schoenberg, Stefan O.; Henzler, ThomasRADIOLOGY, 2014, 273(2): 373-382.被引 152
  • Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol
    Albrecht, Moritz H.; Nance, John W.; Schoepf, U. Joseph*; Jacobs, Brian E.; Bayer, Richard R., II; Litwin, Sheldon E.; Reynolds, Michael A.; Otani, Katharina; Mangold, Stefanie; Varga-Szemes, Akos; De Santis, Domenico; Eid, Marwen; Apfaltrer, Georg; Tesche, Christian; Goeller, Markus; Vogl, Thomas J.; De Cecco, Carlo N.European Radiology, 2018, 28(5): 2134-2142.被引 20
查看全部 →

发表信息

论文状态
公开发表
期刊
European Radiology
发表日期
2016-10
卷期
第 26 卷, 第 10 期
页码
3608-3616
DOI
10.1007/s00330-015-4191-4
语言
ENGLISH
成果收录
SCIE
资助标注
Astellas; Bayer; Bracco; GE; Medrad; Siemens

作者

  • M

    Mangold, Stefanie (第一作者)

  • W

    Wichmann, Julian L.

查看全部 10 位作者收起作者
  • S

    Schoepf, U. Joseph (通讯)

  • P

    Poole, Zachary B.

  • C

    Canstein, Christian

  • V

    Varga-Szemes, Akos

  • C

    Caruso, Damiano

  • B

    Bamberg, Fabian

  • N

    Nikolaou, Konstantin

  • D

    De Cecco, Carlo N.

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417