Lung-Optimized Deep- Learning-Based Reconstruction for Ultralow-Dose CT

Goto, Makoto; Nagayama, Yasunori*; Sakabe, Daisuke; Emoto, Takafumi; Kidoh, Masafumi; Oda, Seitaro; Nakaura, Takeshi; Taguchi, Narumi; Funama, Yoshinori; Takada, Sentaro; Uchimura, Ryutaro; Hayashi, Hidetaka; Hatemura, Masahiro; Kawanaka, Koichi; Hirai, Toshinori
ACADEMIC RADIOLOGY2023-3DOI: 10.1016/j.acra.2022.04.025
12被引13阅读
引用收藏
分享

摘要

Rationale and Objectives: To evaluate the image properties of lung-specialized deep-learning-based reconstruction (DLR) and its appli-cability in ultralow-dose CT (ULDCT) relative to hybrid-(HIR) and model-based iterative-reconstructions (MBIR).Materials and Methods: An anthropomorphic chest phantom was scanned on a 320-row scanner at 50-mA (low-dose-CT 1 [LDCT-1]), 25-mA (LDCT-2), and 10-mA (ULDCT). LDCT were reconstructed with HIR; ULDCT images were reconstructed with HIR (ULDCT-HIR), MBIR (ULDCT-MBIR), and DLR (ULDCT-DLR). Image noise and contrast-to-noise ratio (CNR) were quantified. With the LDCT images as reference standards, ULDCT image qualities were subjectively scored on a 5-point scale (1 = substantially inferior to LDCT-2, 3 = compara-ble to LDCT-2, 5 = comparable to LDCT-1). For task-based image quality analyses, a physical evaluation phantom was scanned at seven doses to achieve the noise levels equivalent to chest phantom; noise power spectrum (NPS) and task-based transfer TTF) were evaluated. Clinical ULDCT (10-mA) images obtained in 14 nonobese patients were reconstructed with HIR, MBIR, and DLR; the subjective acceptability was ranked. Results: Image noise was lower and CNR was higher in ULDCT-DLR and ULDCT-MBIR than in LDCT-1, LDCT-2, and ULDCT-HIR (p < 0.01). The overall quality of ULDCT-DLR was higher than of ULDCT-HIR and ULDCT-MBIR (p < 0.01), and almost comparable with that of LDCT-2 (mean score: 3.4 +/- 0.5). DLR yielded the highest NPS peak frequency and TTF50% for high-contrast object. In clinical ULDCT images, the subjective acceptability of DLR was higher than of HIR and MBIR (p < 0.01).Conclusion: DLR optimized for lung CT improves image quality and provides possible greater dose optimization opportunity than HIR and MBIR.

学科与关键词

关键词
CTLungDeep-learningImage reconstructionUltralow-dose
相关
加载中…
  • Diagnostic value of deep learning reconstruction for radiation dose reduction at abdominal ultra-high-resolution CT
    Nakamura, Yuko*; Narita, Keigo; Higaki, Toru; Akagi, Motonori; Honda, Yukiko; Awai, KazuoEuropean Radiology, 2021, 31(7): 4700-4709.被引 40
  • The future of CT: deep learning reconstruction
    McLeavy, C. M.; Chunara, M. H.; Gravell, R. J.; Rauf, A.; Cushnie, A.; Talbot, C. Staley; Hawkins, R. M.*Clinical Radiology, 2021, 76(6): 407-415.被引 58
  • Pulmonary nodule volumetric accuracy of a deep learning-based reconstruction algorithm in low-dose computed tomography: A phantom study
    Watanabe, Shota*; Sakaguchi, Kenta; Kitaguchi, Shigetoshi; Ishii, KazunariPHYSICA MEDICA, 2022, 104: 1-9.
查看全部 →

发表信息

论文状态
公开发表
期刊
ACADEMIC RADIOLOGY
发表日期
2023-03
卷期
第 30 卷, 第 3 期
页码
431-440
DOI
10.1016/j.acra.2022.04.025
语言
ENGLISH
成果收录
SCIE
资助标注
Takashi Tsutsumi

作者

  • G

    Goto, Makoto (第一作者)

  • N

    Nagayama, Yasunori (通讯)

查看全部 15 位作者收起作者
  • S

    Sakabe, Daisuke

  • E

    Emoto, Takafumi

  • K

    Kidoh, Masafumi

  • O

    Oda, Seitaro

  • N

    Nakaura, Takeshi

  • T

    Taguchi, Narumi

  • F

    Funama, Yoshinori

  • T

    Takada, Sentaro

  • U

    Uchimura, Ryutaro

  • H

    Hayashi, Hidetaka

  • H

    Hatemura, Masahiro

  • K

    Kawanaka, Koichi

  • H

    Hirai, Toshinori

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417