Purpose: To compare the image properties and pulmonary nodule volumetric accuracies among deep learning -based reconstruction (DLR), filtered back projection (FBP), and hybrid iterative reconstruction (hybrid IR) in low-dose computed tomography (LDCT). Methods: A multipurpose chest phantom containing artificial spherical pulmonary nodules with 5-, 8-, 10-, and 12-mm diameters and Hounsfield units (HUs) of-630 and +100 HU was scanned 20 times at a standard dose, based on a low-dose screening CT trial, and at 1/2, 1/6, and 1/12 of the standard dose. To assess noise reduction performance and volumetric accuracy, the standard deviations (SDs) of the pixel values and volumetric per-centage errors (PEs) were compared among FBP, hybrid IR, and DLR. The noise non-stationarity index (NNSI) was calculated from 20 image replicates and compared among FBP, hybrid IR, and DLR to evaluate noise stationarity.Results: The SD reduction rates for FBP in hybrid IR and DLR were 62 %-85 % and 79 %-90 %, respectively. For the four nodules with +100 HU, the PE of all reconstruction methods was <+/- 25 % (not clinically relevant). For the four nodules with-630 HU, the PEs were equivalent or lower for hybrid IR and DLR than for FBP, and the PE difference between hybrid IR and DLR ranged from 0 % to 7%. The NNSI was significantly higher for DLR than for FBP and hybrid IR (p < 0.01).Conclusions: Greater noise suppression was achieved with DLR than with hybrid IR without compromising nodule volumetric accuracy in LDCT despite the representative noise non-stationarity.

学科与关键词

关键词
Computed tomographyDeep learning -based reconstructionPulmonary nodule volumetryNoise stationarityLow radiation dose
相关
加载中…
  • Evaluating the Efficacy of Deep Learning Reconstruction in Reducing Radiation Dose for Computer-Aided Volumetry for Liver Tumor: A Phantom Study
    Nomura, Masahiko; Ohno, Yoshiharu*; Ito, Yuya; Kimata, Hirona; Fujii, Kenji; Akino, Naruomi; Nagata, Hiroyuki; Ueda, Takahiro; Yoshikawa, Takeshi; Takenaka, Daisuke; Ozawa, YoshiyukiJournal of Computer Assisted Tomography, 2025, 49(1): 23-33.
  • Lung-Optimized Deep- Learning-Based Reconstruction for Ultralow-Dose CT
    Goto, Makoto; Nagayama, Yasunori*; Sakabe, Daisuke; Emoto, Takafumi; Kidoh, Masafumi; Oda, Seitaro; Nakaura, Takeshi; Taguchi, Narumi; Funama, Yoshinori; Takada, Sentaro; Uchimura, Ryutaro; Hayashi, Hidetaka; Hatemura, Masahiro; Kawanaka, Koichi; Hirai, ToshinoriACADEMIC RADIOLOGY, 2023, 30(3): 431-440.被引 12
  • Diagnostic validation of a deep learning nodule detection algorithm in low-dose chest CT: determination of optimized dose thresholds in a virtual screening scenario
    Peters, Alan A.*; Huber, Adrian T.; Obmann, Verena C.; Heverhagen, Johannes T.; Christe, Andreas; Ebner, LukasEuropean Radiology, 2022, 32(6): 4324-4332.被引 8
查看全部 →

发表信息

论文状态
公开发表
期刊
PHYSICA MEDICA
发表日期
2022-12
卷期
第 104 卷
页码
1-9
DOI
10.1016/j.ejmp.2022.10.024
语言
ENGLISH
期刊等级
3区
成果收录
SCIE

作者

  • W

    Watanabe, Shota (通讯) (第一作者)

  • S

    Sakaguchi, Kenta

查看全部 4 位作者收起作者
  • K

    Kitaguchi, Shigetoshi

  • I

    Ishii, Kazunari

登录解锁更多功能

  • 收藏这篇,随时在“我的 · 收藏”找回
  • 认领你的成果,生成推广素材
  • 关注作者获取最新成果
  • 加入项目组、协同写作
注册 / 登录

产品服务

  • 科研之友
  • 创新城
  • 科创云

服务支持

  • 帮助中心
  • 隐私政策
  • 服务条款

联系方式

在线客服:【】
客服热线:400-1616-289
电子邮箱:support@scholarmate.com

关注或下载科研之友

微信二维码
微信公众号
客户端下载二维码
下载客户端
科研成果科研人员科研机构科研动态爱瑞思软件

©2026 深圳市科研之友网络服务有限公司

公安备案图标粤公网安备 44030502000213
粤ICP备 16046710 号粤B2-20110417